R4F24278NVFQU Renesas Electronics America, R4F24278NVFQU Datasheet - Page 974

no-image

R4F24278NVFQU

Manufacturer Part Number
R4F24278NVFQU
Description
MCU 512K/48K 2.7-5.5V 144-LQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2400r
Datasheet

Specifications of R4F24278NVFQU

Core Processor
H8S/2600
Core Size
16/32-Bit
Speed
33MHz
Connectivity
EBI/EMI, I²C, IrDA, SCI, Smart Card, SPI, SSU, UART/USART
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
98
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Eeprom Size
-
Ram Size
64K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 16x10b; D/A 2x8b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
144-LQFP
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
R4F24278NVFQU
Manufacturer:
REALTEK
Quantity:
2 300
Part Number:
R4F24278NVFQU
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 16 Serial Communication Interface (SCI, IrDA, CRC)
Page 944 of 1448
No
No
Read receive data in RDR, and
clear RDRF flag in SSR to 0
PER ∨ FER ∨ ORER = 1?
Read RDRF flag in SSR
Clear RE bit in SCR to 0
Read ORER, PER, and
Figure 16.9 Sample Serial Reception Data Flowchart (1)
All data received?
FER flags in SSR
Start of reception
Initialization
RDRF = 1?
<End>
Yes
Yes
No
(Continued on next page)
Error handling
Yes
[1]
[2]
[4]
[5]
[3]
[1]
[2] [3]
[4]
[5]
SCI initialization:
The RxD pin is automatically
designated as the receive data
input pin.
break detection:
If a receive error occurs, read the
ORER, PER, and FER flags in
SSR to identify the error. After
performing the appropriate error
processing, ensure that the
ORER, PER, and FER flags are
all cleared to 0. Reception cannot
be resumed if any of these flags
are set to 1. In the case of a
framing error, a break can be
detected by reading the value of
the input port corresponding to
the RxD pin.
SCI status check and receive
data read :
Read SSR and check that RDRF
= 1, then read the receive data in
RDR and clear the RDRF flag to
0. Transition of the RDRF flag
from 0 to 1 can also be identified
by an RXI interrupt.
Serial reception continuation
procedure:
To continue serial reception,
before the stop bit for the current
frame is received, read the
RDRF flag, read RDR, and clear
the RDRF flag to 0. The RDRF
flag is cleared automatically
when the DMAC or DTC is
activated by an RXI interrupt and
the RDR value is read.
Receive error handling and
H8S/2427, H8S/2427R, H8S/2425 Group
REJ09B0565-0100 Rev. 1.00
Jul 22, 2010

Related parts for R4F24278NVFQU