SAM9263 Atmel Corporation, SAM9263 Datasheet - Page 668

no-image

SAM9263

Manufacturer Part Number
SAM9263
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM9263

Flash (kbytes)
0 Kbytes
Pin Count
324
Max. Operating Frequency
240 MHz
Cpu
ARM926
Hardware Qtouch Acquisition
No
Max I/o Pins
160
Ext Interrupts
160
Usb Transceiver
3
Usb Speed
Full Speed
Usb Interface
Host, Device
Spi
2
Twi (i2c)
1
Uart
4
Can
1
Ssc
2
Ethernet
1
Sd / Emmc
2
Graphic Lcd
Yes
Video Decoder
No
Camera Interface
Yes
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
96
Self Program Memory
NO
External Bus Interface
2
Dram Memory
sdram
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Fpu
No
Mpu / Mmu
No / Yes
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
37.7.3.3
Figure 37-12. Receive with Overwrite Mailbox
37.7.3.4
6249I–ATARM–3-Oct-11
(CAN_MSRx)
(CAN_MSRx)
CAN_MDHx)
(CAN_MCRx)
(CAN_MDLx
CAN BUS
MRDY
MTCR
Receive with Overwrite Mailbox
Chaining Mailboxes
MMI
A mailbox is in Receive with Overwrite Mode once the MOT field in the CAN_MMRx register has
been configured. Message ID and Message Acceptance masks must be set before Receive
Mode is enabled.
After Receive Mode is enabled, the MRDY flag in the CAN_MSR register is automatically
cleared until the first message is received. When the first message has been accepted by the
mailbox, the MRDY flag is set. An interrupt is pending for the mailbox while the MRDY flag is set.
This interrupt is masked depending on the mailbox flag in the CAN_IMR global register.
If a new message is received while the MRDY flag is set, this new message is stored in the mail-
box data register, overwriting the previous message. The MMI flag in the CAN_MSRx register
notifies the software that a message has been dropped by the mailbox. This flag is cleared when
reading the CAN_MSRx register.
The CAN controller may store a new message in the CAN data registers while the application
reads them. To check that CAN_MDHx and CAN_MDLx do not belong to different messages,
the application must check the MMI field in the CAN_MSRx register before and after reading
CAN_MDHx and CAN_MDLx. If the MMI flag is set again after the data registers have been
read, the software application has to re-read CAN_MDHx and CAN_MDLx (see
Several mailboxes may be used to receive a buffer split into several messages with the same ID.
In this case, the mailbox with the lowest number is serviced first. In the receive and receive with
overwrite modes, the field PRIOR in the CAN_MMRx register has no effect. If Mailbox 0 and
Mailbox 5 accept messages with the same ID, the first message is received by Mailbox 0 and the
second message is received by Mailbox 5. Mailbox 0 must be configured in Receive Mode (i.e.,
the first message received is considered) and Mailbox 5 must be configured in Receive with
Overwrite Mode. Mailbox 0 cannot be configured in Receive with Overwrite Mode; otherwise, all
messages are accepted by this mailbox and Mailbox 5 is never serviced.
Message 1
Reading CAN_MDHx & CAN_MDLx
Reading CAN_MSRx
Message 1
Message 2
Message 2
Message 3
Writing CAN_MCRx
Message 3
Message 4
Message ID = CAN_MIDx
AT91SAM9263
Message 4
Figure
37-12).
668

Related parts for SAM9263