SAM9263 Atmel Corporation, SAM9263 Datasheet - Page 687

no-image

SAM9263

Manufacturer Part Number
SAM9263
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM9263

Flash (kbytes)
0 Kbytes
Pin Count
324
Max. Operating Frequency
240 MHz
Cpu
ARM926
Hardware Qtouch Acquisition
No
Max I/o Pins
160
Ext Interrupts
160
Usb Transceiver
3
Usb Speed
Full Speed
Usb Interface
Host, Device
Spi
2
Twi (i2c)
1
Uart
4
Can
1
Ssc
2
Ethernet
1
Sd / Emmc
2
Graphic Lcd
Yes
Video Decoder
No
Camera Interface
Yes
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
96
Self Program Memory
NO
External Bus Interface
2
Dram Memory
sdram
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Fpu
No
Mpu / Mmu
No / Yes
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
This flag is automatically reset when above condition is not satisfied. Refer to
page 661
• BOFF: Bus Off Mode
0 = CAN controller is not in Bus Off Mode.
1 = CAN controller is in Bus Off Mode.
This flag is set depending on TEC counter value. A node is bus off when TEC counter is greater or equal to 256 (decimal).
This flag is automatically reset when above condition is not satisfied. Refer to
page 661
• SLEEP: CAN controller in Low power Mode
0 = CAN controller is not in low power mode.
1 = CAN controller is in low power mode.
This flag is automatically reset when Low power mode is disabled
• WAKEUP: CAN controller is not in Low power Mode
0 = CAN controller is in low power mode.
1 = CAN controller is not in low power mode.
When a WAKEUP event occurs, the CAN controller is synchronized with the bus activity. Messages can be transmitted or
received. The CAN controller clock must be available when a WAKEUP event occurs. This flag is automatically reset when
the CAN Controller enters Low Power mode.
• TOVF: Timer Overflow
0 = The timer has not rolled-over FFFFh to 0000h.
1 = The timer rolls-over FFFFh to 0000h.
This flag is automatically cleared by reading CAN_SR register.
• TSTP Timestamp
0 = No bus activity has been detected.
1 = A start of frame or an end of frame has been detected (according to the TEOF field in the CAN_MR register).
This flag is automatically cleared by reading the CAN_SR register.
• CERR: Mailbox CRC Error
0 = No CRC error occurred during a previous transfer.
1 = A CRC error occurred during a previous transfer.
A CRC error has been detected during last reception.
This flag is automatically cleared by reading CAN_SR register.
• SERR: Mailbox Stuffing Error
0 = No stuffing error occurred during a previous transfer.
1 = A stuffing error occurred during a previous transfer.
A form error results from the detection of more than five consecutive bit with the same polarity.
This flag is automatically cleared by reading CAN_SR register.
6249I–ATARM–3-Oct-11
for more information.
for more information.
Section 37.6.4.6 “Error Interrupt Handler” on
Section 37.6.4.6 “Error Interrupt Handler” on
AT91SAM9263
687

Related parts for SAM9263