SAM9263 Atmel Corporation, SAM9263 Datasheet - Page 678

no-image

SAM9263

Manufacturer Part Number
SAM9263
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM9263

Flash (kbytes)
0 Kbytes
Pin Count
324
Max. Operating Frequency
240 MHz
Cpu
ARM926
Hardware Qtouch Acquisition
No
Max I/o Pins
160
Ext Interrupts
160
Usb Transceiver
3
Usb Speed
Full Speed
Usb Interface
Host, Device
Spi
2
Twi (i2c)
1
Uart
4
Can
1
Ssc
2
Ethernet
1
Sd / Emmc
2
Graphic Lcd
Yes
Video Decoder
No
Camera Interface
Yes
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
96
Self Program Memory
NO
External Bus Interface
2
Dram Memory
sdram
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Fpu
No
Mpu / Mmu
No / Yes
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
37.8.1
Name:
Address:
Access Type:Read-write
• CANEN: CAN Controller Enable
0 = The CAN Controller is disabled.
1 = The CAN Controller is enabled.
• LPM: Disable/Enable Low Power Mode
w Power Mode.
1 = Enable Low Power M
CAN controller enters Low Power Mode once all pending messages have been transmitted.
• ABM: Disable/Enable Autobaud/Listen mode
0 = Disable Autobaud/listen mode.
1 = Enable Autobaud/listen mode.
• OVL: Disable/Enable Overload Frame
0 = No overload frame is generated.
1 = An overload frame is generated after each successful reception for mailboxes configured in Receive with/without over-
write Mode, Producer and Consumer.
• TEOF: Timestamp messages at each end of Frame
0 = The value of CAN_TIM is captured in the CAN_TIMESTP register at each Start Of Frame.
1 = The value of CAN_TIM is captured in the CAN_TIMESTP register at each End Of Frame.
• TTM: Disable/Enable Time Triggered Mode
0 = Time Triggered Mode is disabled.
1 = Time Triggered Mode is enabled.
• TIMFRZ: Enable Timer Freeze
0 = The internal timer continues to be incremented after it reached 0xFFFF.
1 = The internal timer stops incrementing after reaching 0xFFFF. It is restarted after a timer reset. See
nal Timer Counter” on page
6249I–ATARM–3-Oct-11
DRPT
31
23
15
7
CAN Mode Register
CAN_MR
0xFFFAC000
TIMFRZ
30
22
14
6
675.
TTM
29
21
13
5
TEOF
28
20
12
4
OVL
27
19
11
3
ABM
26
18
10
2
AT91SAM9263
LPM
25
17
9
1
“Freezing the Inter-
CANEN
24
16
8
0
678