PEF 20532 F V1.3 Infineon Technologies, PEF 20532 F V1.3 Datasheet - Page 108

no-image

PEF 20532 F V1.3

Manufacturer Part Number
PEF 20532 F V1.3
Description
IC COMM CTRLR 2CH SER TQFP-100
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEF 20532 F V1.3

Function
Serial Optimized Communications Controller
Interface
ASYNC, BISYNC, HDLC, PPP
Number Of Circuits
2
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
50mA
Power (watts)
150mW
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
100-LFQFP
Includes
Automatic Flag Detection and Transmission, Baud Rate Generator, On-Chip Clock Generation, Receive Line Status Detection
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
PEF20532FV1.3X
PEF20532FV13XP
SP000007511
PEB 20532
PEF 20532
Detailed Protocol Description
Transmission of Frames:
The SCC autonomously transmits S commands and S responses in the auto mode.
Either transparent or I-frames can be transmitted by the user. The software timer has to
be operated in the internal timer mode to transmit I-frames. After the frame has been
transmitted, the timer is self-started, the XFIFO is inhibited, and the SCC waits for the
arrival of a positive acknowledgement. This acknowledgement can be provided by
means of an S- or I-frame.
t
If no positive acknowledgement is received during time
, the SCC transmits an S-
1
command (p = ‘1’), which must be answered by an S-response (f = ‘1’). If the S-response
is not received, the process is performed n1 times (in HDLC known as N2, refer to
register TIMR3).
Upon the arrival of an acknowledgement or after the completion of this poll procedure
the XFIFO is enabled and an interrupt is generated. Interrupts may be triggered by the
following:
• message has been positively acknowledged (ALLS interrupt)
• message must be repeated (XMR interrupt)
• response has not been received (TIN interrupt).
In automode, only when the ALLS interrupt has been issued data of a new frame may
be provided to the XFIFO!
Upon arrival of an RNR frame, the software timer is started and the status of the remote
t
station is polled periodically after expiration of
, until the status ‘receive ready’ has been
1
detected. The user is informed via the appropriate interrupt. If no response is received
after n1 times, a TIN interrupt, and
t
clock periods thereafter an ALLS interrupt is
1
generated and the process is terminated.
Note: The internal timer mode should only be used in the auto mode.
Transparent frames can be transmitted in all operating modes.
Data Sheet
108
2000-09-14

Related parts for PEF 20532 F V1.3