MCF5307CFT66B Freescale Semiconductor, MCF5307CFT66B Datasheet - Page 248

no-image

MCF5307CFT66B

Manufacturer Part Number
MCF5307CFT66B
Description
IC MPU 32BIT 66MHZ COLDF 208FQFP
Manufacturer
Freescale Semiconductor
Series
MCF530xr
Datasheets

Specifications of MCF5307CFT66B

Core Processor
Coldfire V3
Core Size
32-Bit
Speed
66MHz
Connectivity
EBI/EMI, I²C, UART/USART
Peripherals
DMA, POR, WDT
Number Of I /o
16
Program Memory Type
ROMless
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
208-FQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Data Converters
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCF5307CFT66B
Manufacturer:
FREESCAL
Quantity:
154
Part Number:
MCF5307CFT66B
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Freescale Semiconductor, Inc.
Asynchronous Operation
the next bus cycle are often available before the current cycle completes. The two addresses
are compared at the end of the cycle to determine if the next address hits the same page. If
so, RAS remains asserted. If not, or if no access is pending, RAS is precharged before the
next bus cycle is active on the external bus. As a result, a page miss suffers no penalty.
Single accesses not followed by a hit in the page look like non-page-mode accesses.
Figure 11-9 shows a write cycle followed by a read cycle in continuous page mode. The
read hits in the same page as the write so RAS is not negated before the second cycle. Note
that the row address does not appear on the pins for a bus cycle that hits in the page. Column
addresses are immediately multiplexed onto the pins. The third bus cycle is a page miss, so
RAS is precharged before the end of the bus cycle and no extra precharge delay is incurred.
BCLKO
A[31:0]
Row
Column
Column
Row
Column
Page Miss
Page Hit
RAS[1] or [0]
RNCN=1
RCD=0
CAS=01
CAS[3:0]
DRAMW
D[31:0]
Bus Cycle 1
Bus Cycle 2
Bus Cycle 3
Figure 11-9. Continuous Page-Mode Operation
If a write cycle hits in the page, CAS must be delayed by one clock to allow data to become
valid, as shown in Figure 11-10.
11-14
MCF5307 User’s Manual
For More Information On This Product,
Go to: www.freescale.com

Related parts for MCF5307CFT66B