TMP89xy60UG/FG Toshiba, TMP89xy60UG/FG Datasheet - Page 177

no-image

TMP89xy60UG/FG

Manufacturer Part Number
TMP89xy60UG/FG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP89xy60UG/FG

Package
LQFP64/QFP64
Rom Types (m=mask,p=otp,f=flash)
M/F
Rom Size
32/60
Ram Size
3K
Driver Led
8
Driver Lcd
-
Spi/sio Channels
-
Uart/sio Channels
2
I2c/sio Channels
1
High-speed Serial Output
-
Adc 8-bit Channels
-
Adc 10-bit Channels
16
Da Converter Channels
-
Timer Counter 18-bit Channel
-
Timer Counter 16-bit Channel
2
Timer Counter 8-bit Channel
4
Motor Channels
-
Watchdog Timer
Y
Dual Clock
Y
Clock Gear
Y
Number Of I/o Ports
58
Power Supply (v)
4.3 to 5.5
RB002
13.4.4
13.4.4.1
13.4.4.2
13.4.4.3
13.4.4.4
the input pulse to the TCA0 pin (window pulse) and the internal clock.
In the window mode, the up counter counts up at the rising edge of the pulse that is logical anded product of
Window mode
source clock at TA0MOD<TA0CK>.
TA0MOD<TA0TED> to "0" enables counting up as long as the window pulse is at the "H" level. Setting
TA0MOD<TA0TED> to "1" enables counting up as long as the window pulse is at the "L" level.
in port settings.
and TA0CR<TA0OVE> is disabled. Be sure to complete the required mode settings before starting the timer.
the up counter increments according to the source clock selected at TA0MOD<TA0CK>. When a match
between the up counter value and the value set to timer register A (TA0DRA) is detected, an INTTCA0
interrupt request is generated and the up counter is cleared to "0x0000". After being cleared, the up counter
restarts counting.
Define a frequency pulse that is sufficiently lower than the programmed internal source clock.
cleared to "0x0000".
Setting the operation mode selection TA0MOD<TA0M> to "101" activates the window mode. Select the
Select the window pulse level at the trigger edge input selection TA0MOD<TA0TED>. Setting
Note that this mode uses the TA0 input pin, and the TCA0 pin must be set to the input mode beforehand
The operation is started by setting TA0CR<TA0S> to "1". After the timer is started, writing to TA0MOD
After the operation is started, when the level selected at TA0MOD<TA0TED> is input to the TCA0 pin,
The maximum frequency to be supplied must be slow enough for the program to analyze the count value.
Setting TA0CR<TA0S> to "0" during the timer operation causes the up counter to stop counting and be
Refer to "13.4.1.3 Auto capture".
Refer to "13.4.1.4 Register buffer configuration".
Setting
Operation
Auto capture
Register buffer configuration
Page 161
TMP89FS60

Related parts for TMP89xy60UG/FG