TMP89xy60UG/FG Toshiba, TMP89xy60UG/FG Datasheet - Page 379

no-image

TMP89xy60UG/FG

Manufacturer Part Number
TMP89xy60UG/FG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP89xy60UG/FG

Package
LQFP64/QFP64
Rom Types (m=mask,p=otp,f=flash)
M/F
Rom Size
32/60
Ram Size
3K
Driver Led
8
Driver Lcd
-
Spi/sio Channels
-
Uart/sio Channels
2
I2c/sio Channels
1
High-speed Serial Output
-
Adc 8-bit Channels
-
Adc 10-bit Channels
16
Da Converter Channels
-
Timer Counter 18-bit Channel
-
Timer Counter 16-bit Channel
2
Timer Counter 8-bit Channel
4
Motor Channels
-
Watchdog Timer
Y
Dual Clock
Y
Clock Gear
Y
Number Of I/o Ports
58
Power Supply (v)
4.3 to 5.5
RA003
Table 22-9 Transfer Formats of the Flash Memory Read Command
BOOT
ROM
Note 1: "0x** × 3" means that the device goes into an idle state after transmitting 3 bytes of 0x**. For further information, refer to
Note 2: For information on checksums, refer to "22.10 Checksum (SUM)". For information on passwords, refer to "22.12.1 Pass-
Note 3: If the area 0xFFE0 through 0xFFFF is all 0xFF, password authentication is not performed and, therefore, the password
Note 4: If the security program is enabled in flash memory or if a password error occurs, the TMP89FS60 stops communication,
Note 5: If a communication error occurs during the transfer of a password address or a password string, the TMP89FS60 stops
Note 6: If the number of bytes received at the m-th + 7 byte, m-th + 9 byte or m-th + 11 byte is more than 0x000000 or the size
m-th + 11 byte
m-th + 12 byte
m-th + 13 byte
:
n-th - 2 byte
n-th - 1 byte
n-th byte
n-th + 1 byte
Transfer byte
Table 22-18.
words".
string need not be transmitted. The password count storage address and password comparison start address, however,
must be specified, even for a blank product. If the password count storage address and/or password comparison start
address are/is incorrect, a password error occurs; the TMP89FS60 stops communication and goes into an idle state.
Therefore, if a password error occurs, initialize the TMP89FS60 by using the RESET pin, and restart the serial PROM
mode.
and goes into an idle state. Therefore, if a password error occurs, initialize the TMP89FS60 by using the RESET pin, and
restart the serial PROM mode.
communication and goes into an idle state. Therefore, when a password error occurs, initialize the TMP89FS60 by using
the RESET pin, and restart the serial PROM mode.
of internal memory, the TMP89FS60 stops communication and goes into an idle state.
Number of bytes to read 07 to 00
-
-
(Wait for the next operation command data)
Transfer data from the external controller to
TMP89FS60
Page 363
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate
-
OK: No data transmitted
Error: No data transmitted
Memory data
Memory data
OK: Checksum (high)
Error: No data transmitted
OK: Checksum (low)
Error: No data transmitted
-
Transfer data from TMP89FS60 to the ex-
ternal controller
TMP89FS60

Related parts for TMP89xy60UG/FG