TMP89xy60UG/FG Toshiba, TMP89xy60UG/FG Datasheet - Page 380

no-image

TMP89xy60UG/FG

Manufacturer Part Number
TMP89xy60UG/FG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP89xy60UG/FG

Package
LQFP64/QFP64
Rom Types (m=mask,p=otp,f=flash)
M/F
Rom Size
32/60
Ram Size
3K
Driver Led
8
Driver Lcd
-
Spi/sio Channels
-
Uart/sio Channels
2
I2c/sio Channels
1
High-speed Serial Output
-
Adc 8-bit Channels
-
Adc 10-bit Channels
16
Da Converter Channels
-
Timer Counter 18-bit Channel
-
Timer Counter 16-bit Channel
2
Timer Counter 8-bit Channel
4
Motor Channels
-
Watchdog Timer
Y
Dual Clock
Y
Clock Gear
Y
Number Of I/o Ports
58
Power Supply (v)
4.3 to 5.5
22.8
Operation Commands
RA003
Table 22-10 Transfer Formats of the RAM Loader Command
22.8.4
BOOT
ROM
RAM
Note 1: "0x** × 3" means that the device goes into an idle state after transmitting 3 bytes of 0x**. For further information, refer to
Note 2: For information on the Intel Hex format, refer to "22.11 Intel Hex Format (Binary)". For information on checksums, refer
Note 3: If the area 0xFFE0 through 0xFFFF is all 0xFF, password authentication is not performed and, therefore, the password
Note 4: After sending a password string, do not send the end record only. If the TMP89FS60 receives the end record after receiving
1st byte
2nd byte
3rd byte
4th byte
5th byte
6th byte
7th byte
8th byte
9th byte
10th byte
11th byte
12th byte
13th byte
14th byte
15th byte
16th byte
17th byte
18th byte
19th byte
:
m-th byte
m-th + XX byte
:
n-th - 2 byte
n-th - 1 byte
n-th byte
-
Transfer byte
Table 22-10 shows the transfer formats of the RAM loader command.
RAM loader command (operation command: 0x60)
Table 22-18.
to "22.10 Checksum (SUM)". For information on passwords, refer to "22.12.1 Passwords".
string need not be transmitted. The password count storage address and password comparison start address, however,
must be specified, even for a blank product. If the password count storage address and/or password comparison start
address are/is incorrect, a password error occurs; the TMP89FS60 stops communication and goes into an idle state.
Therefore, if a password error occurs, initialize the TMP89FS60 by using the RESET pin, and restart the serial PROM
mode.
a password string, it may malfunction.
Matching data 1 (0x86 or 0x30)
-
Matching data 2 (0x79 or 0xCF)
-
Operation command data (0x60)
-
Password count storage address 23 to 16
Password count storage address 15 to 08
Password count storage address 07 to 00
Password comparison start address 23 to 16
Password comparison start address 15 to 08
Password comparison start address 07 to 00
Password string
-
Intel Hex format (binary)
-
-
The program jumps to the start address of RAM in which the first transferred data is written, and executes itself.
Transfer data from the external controller to
TMP89FS60
Page 364
Automatic adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate
- (Automatic baud rate adjustment)
OK: Echo back data (0x86 or 0x30)
Error: No data transmitted
-
OK: Echo back data (0x79 or 0xCF)
Error: No data transmitted
-
OK: Echo back data (0x60)
Error: 0xA1 × 3, 0xA3 × 3, 0x63 × 3 (note 1)
-
OK: No data transmitted
Error: No data transmitted
-
OK: No data transmitted
Error: No data transmitted
-
OK: No data transmitted
Error: No data transmitted
-
OK: No data transmitted
Error: No data transmitted
-
OK: No data transmitted
Error: No data transmitted
-
OK: No data transmitted
Error: No data transmitted
-
OK: No data transmitted
Error: No data transmitted
-
-
OK: Checksum (high) (note 3)
Error: No data transmitted
OK: Checksum (low) (note 3)
Error: No data transmitted
Transfer data from TMP89FS60 to the ex-
ternal controller
TMP89FS60

Related parts for TMP89xy60UG/FG