TMP89xy60UG/FG Toshiba, TMP89xy60UG/FG Datasheet - Page 389

no-image

TMP89xy60UG/FG

Manufacturer Part Number
TMP89xy60UG/FG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP89xy60UG/FG

Package
LQFP64/QFP64
Rom Types (m=mask,p=otp,f=flash)
M/F
Rom Size
32/60
Ram Size
3K
Driver Led
8
Driver Lcd
-
Spi/sio Channels
-
Uart/sio Channels
2
I2c/sio Channels
1
High-speed Serial Output
-
Adc 8-bit Channels
-
Adc 10-bit Channels
16
Da Converter Channels
-
Timer Counter 18-bit Channel
-
Timer Counter 16-bit Channel
2
Timer Counter 8-bit Channel
4
Motor Channels
-
Watchdog Timer
Y
Dual Clock
Y
Clock Gear
Y
Number Of I/o Ports
58
Power Supply (v)
4.3 to 5.5
RA003
Table 22-17 Flash Memory Security Setting Command
22.8.9
BOOT
ROM
Note 1: "xxH × 3" means that the device goes into an idle state after transmitting 3 bytes of xxH.
Note 2: For information on passwords, refer to "22.12.1 Passwords".
Note 3: If the flash memory security setting command is executed for a blank product or if a password error occurs for a non-blank
Note 4: If a communication error occurs during the transfer of a password address or password string, the TMP89FS60 stops
Note 5: If the flash memory security is not enabled, it becomes possible to read ROM data freely in parallel PROM mode. Make
1st byte
2nd byte
3rd byte
4th byte
5th byte
6th byte
7th byte
8th byte
9th byte
10th byte
11th byte
12th byte
13th byte
14th byte
15th byte
16th byte
17th byte
18th byte
19th byte
:
m-th byte
n-th byte
n-th + 1 byte
Transfer byte
Table 22-17 shows the flash memory security setting command.
Flash memory security setting command (0xFA)
product, the TMP89FS60 stops communication and goes into an idle state. Therefore, if a password error occurs, initialize
the TMP89FS60 by using the RESET pin, and restart the serial PROM mode.
communication and goes into an idle state. Therefore, if a password error occurs, initialize the TMP89FS60 by using the
RESET pin, and restart the serial PROM mode.
sure that you enable the flash memory security in mass production.
Matching data 1 (0x86 or 0x30)
-
Matching data 2 (0x79 or 0xCF)
-
Operation command data (0xFA)
-
Password count storage address 23 to 16
Password count storage address 15 to 08
Password count storage address 07 to 00
Password comparison start address 23 to 16
Password comparison start address 15 to 08
Password comparison start address 07 to 00
Password string
-
-
(Wait for the next command data)
Transfer data from the external controller to
TMP89FS60
Page 373
Automatic adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate
- (Automatic baud rate adjustment)
OK: Echo back data (0x86 or 0x30)
Error: No data transmitted
-
OK: Echo back data (0x79 or 0xCF)
Error: No data transmitted
-
OK: Echo back data (0xFA)
Error: 0xA1 × 3, 0xA3 × 3, 0x63 × 3 (note 1)
-
OK: No data transmitted
Error: No data transmitted
-
OK: No data transmitted
Error: No data transmitted
-
OK: No data transmitted
Error: No data transmitted
-
OK: No data transmitted
Error: No data transmitted
-
OK: No data transmitted
Error: No data transmitted
-
OK: No data transmitted
Error: No data transmitted
-
OK: No data transmitted
Error: No data transmitted
OK: 0xFB (note 3)
Error: No data transmitted
-
Transfer data from TMP89FS60 to the ex-
ternal controller
TMP89FS60

Related parts for TMP89xy60UG/FG