DF2110BVTE10 Renesas Electronics America, DF2110BVTE10 Datasheet - Page 299

MCU 3V 64K 100-TQFP

DF2110BVTE10

Manufacturer Part Number
DF2110BVTE10
Description
MCU 3V 64K 100-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2100r
Datasheet

Specifications of DF2110BVTE10

Core Processor
H8S/2000
Core Size
16-Bit
Speed
10MHz
Connectivity
Host Interface (LPC), I²C, SCI
Peripherals
POR, PWM, WDT
Number Of I /o
82
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Data Converters
-
Other names
HD64F2110BVTE10
HD64F2110BVTE10

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF2110BVTE10V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Reception cannot be resumed while a receive error flag is set to 1. Accordingly, clear the ORER,
FER, PER, and RDRF bits to 0 before resuming reception. Figure 12.19 shows a sample flowchart
for serial data reception.
[3]
No
No
Read receive data in RDR and
clear RDRF flag in SSR to 0
Clear ORER flag in SSR to 0
Read ORER flag in SSR
Clear RE bit in SCR to 0
Read RDRF flag in SSR
Overrun error processing
All data received?
Figure 12.19 Sample Serial Reception Flowchart
Error processing
Start reception
Initialization
ORER = 1
RDRF = 1
<End>
<End>
Yes
Yes
No
(Continued below)
Error processing
Yes
[2]
[1]
[3]
[4]
[5]
Section 12 Serial Communication Interface (SCI)
[1] SCI initialization:
[2] [3] Receive error processing:
[4] SCI status check and receive data
[5] Serial reception continuation
Rev. 2.00 Mar 21, 2006 page 259 of 518
The RxD pin is automatically
designated as the receive data input
pin.
If a receive error occurs, read the
ORER flag in SSR, and after
performing the appropriate error
processing, clear the ORER flag to 0.
Transfer cannot be resumed if the
ORER flag is set to 1.
read:
Read SSR and check that the RDRF
flag is set to 1, then read the receive
data in RDR and clear the RDRF flag
to 0.
Transition of the RDRF flag from 0 to 1
can also be identified by an RXI
interrupt.
procedure:
To continue serial reception, before
the MSB (bit 7) of the current frame is
received, reading the RDRF flag,
reading RDR, and clearing the RDRF
flag to 0 should be finished.
REJ09B0299-0200

Related parts for DF2110BVTE10