DS3181 Maxim Integrated Products, DS3181 Datasheet - Page 195

no-image

DS3181

Manufacturer Part Number
DS3181
Description
Network Controller & Processor ICs DS3-E3 ATM-Packet PH Y with Built-in Line
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS3181

Product
Framer
Number Of Transceivers
1
Data Rate
44.736 Mbps
Supply Voltage (max)
3.465 V
Supply Voltage (min)
3.135 V
Supply Current (max)
280 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Package / Case
TEBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS3181+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS3181N+
Manufacturer:
Maxim Integrated
Quantity:
10 000
DS3181/DS3182/DS3183/DS3184
10.15.4.1 Receive PRBS Synchronization
PRBS synchronization synchronizes the receive pattern generator to the incoming PRBS or QRSS pattern. The
receive pattern generator is synchronized by loading 32 data stream bits into the receive pattern generator, and
then checking the next 32 data stream bits. Synchronization is achieved if all 32 bits match the incoming pattern. If
at least six incoming bits in the current 64-bit window do not match the receive pattern generator, automatic pattern
re-synchronization is initiated. Automatic pattern re-synchronization can be disabled.
See
Figure 10-55
for the PRBS synchronization diagram.
Figure 10-55. PRBS Synchronization State Diagram
Sync
1 bit error
Verify
Load
32 bits loaded
10.15.4.2 Receive Repetitive Pattern Synchronization
Repetitive pattern synchronization synchronizes the receive pattern generator to the incoming repetitive pattern.
The receive pattern generator is synchronized by searching each incoming data stream bit position for the
repetitive pattern, and then checking the next 32 data stream bits. Synchronization is achieved if all 32 bits match
the incoming pattern. If at least six incoming bits in the current 64-bit window do not match the receive PRBS
pattern generator, automatic pattern re-synchronization is initiated. Automatic pattern re-synchronization can be
disabled. See Figure 10-56 for the repetitive pattern synchronization state diagram.
195

Related parts for DS3181