DS3181 Maxim Integrated Products, DS3181 Datasheet - Page 292

no-image

DS3181

Manufacturer Part Number
DS3181
Description
Network Controller & Processor ICs DS3-E3 ATM-Packet PH Y with Built-in Line
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS3181

Product
Framer
Number Of Transceivers
1
Data Rate
44.736 Mbps
Supply Voltage (max)
3.465 V
Supply Voltage (min)
3.135 V
Supply Current (max)
280 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Package / Case
TEBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS3181+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS3181N+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Bit 7: Receive Alarm Indication on LOF Enable (RAILE) – When 0, an LOF condition does not affect the receive
alarm indication signal (RAI). When 1, an LOF condition will cause the transmit E3 A bit to be set to one if transmit
automatic RAI is enabled.
Bit 6: Receive Alarm Indication on LOS Disable (RAILD) – When 0, an LOS condition will cause the transmit E3
A bit to be set to one if transmit automatic RAI is enabled. When 1, an LOS condition does not affect the RAI
signal.
Bit 5: Receive Alarm Indication on OOF Disable (RAIOD) – When 0, an OOF condition will cause the transmit
E3 A bit to be set to one if transmit automatic RAI is enabled. When 1, an OOF condition does not affect the RAI
signal.
Bit 4: Receive Alarm Indication on AIS Disable (RAIAD) – When 0, an AIS condition will cause the transmit E3
A bit to be set to one if transmit automatic RAI is enabled. When 1, an AIS condition does not affect the RAI signal.
Bit 3: Receive Overhead Masking Disable (ROMD) – When 0, the E3 overhead positions in the outgoing E3
payload will be marked as overhead by RDENn. When 1, the E3 overhead positions in the outgoing E3 payload will
be marked as data by RDENn.
Bits 2 to 1: LOF Integration Period (LIP[1:0]) – These two bits determine the OOF integration period for
declaring LOF.
Bit 0: Force Framer Re-synchronization (FRSYNC) – A 0 to 1 transition forces an OOF condition at the FAS
check. This bit must be cleared and set to one again to force another re-synchronization
00 = OOF is integrated for 3 ms before declaring LOF
01 = OOF is integrated for 2 ms before declaring LOF.
10 = OOF is integrated for 1 ms before declaring LOF
11 = LOF is declared at the same time as OOF
292