UPD78F1233GB-GAH-AX Renesas Electronics America, UPD78F1233GB-GAH-AX Datasheet - Page 416

no-image

UPD78F1233GB-GAH-AX

Manufacturer Part Number
UPD78F1233GB-GAH-AX
Description
MCU 16BIT 78K0R/LX3 64-LQFP
Manufacturer
Renesas Electronics America
Series
78K0R/Ix3r
Datasheet

Specifications of UPD78F1233GB-GAH-AX

Core Processor
78K/0R
Core Size
16-Bit
Speed
40MHz
Connectivity
3-Wire SIO, I²C, LIN, UART/USART
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
50
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
1.5K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD78F1233GB-GAH-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
triangular wave PWM output function with dead time uses master channel 0, slave channel 2, and slave channel 3,
and master channel 4, slave channel 6, and slave channel 7 in combination.
TDRp at the first count clock, after the channel start trigger bit (TSp) is set to 1. Hereafter, counting up and counting
down is switched in accordance with the operation of the master channel. INTTMp is output when TCRp becomes
0001H.
operation is continued hereafter.
the start trigger. When TCRq becomes 0000H, it outputs INTTMq and stops counting until the next start trigger is
input (INTTMp of slave channels 2, 6). INTTMq of slave channels 3, 7 cannot be used, because the number of times
it occurs within the carrier cycle period cannot be specified (0 to 3 times).
operation (INTTMp, INTTMq) of slave channels 2, 6 (duty) and slave channels 3, 7 (dead time). A positive-phase
waveform and a reverse-phase waveform are output by controlling the TOLp and TOLq bits of the TOL0 registers of
slave channels 2, 6 and slave channels 3, 7.
setting TOLp and TOLq. When TOLp or TOLq is set to 0, a positive-phase waveform to which dead time has been
added on the positive logic side of the PWM duty is output. When TOLp or TOLq is set to 1, a reverse-phase
waveform to which dead time has been added on the inverted logic side of the PWM duty is output (TOLq = 1 when
TOLp = 0, and TOLq = 0 when TOLp = 1).
OPMR register.
uses the generation of INTTMp while the TCRp register counts down as the start trigger. The reset condition of TOp
(TOLp = 0) is the generation of INTTMp of slave channels 2, 6 while TCRp counts up.
condition of TOq (TOLq = 0) is the generation of INTTMq by the operation of slave channels 3, 7, which uses the
generation of INTTMp while TCRp counts down as the start trigger.
and 3, 7 by setting TOLp and TOLq.
414
Slave channels 1 and 5 are not used as PWM output functions with dead times.
Dead time is controlled by using slave channel p (p = 2, 6) and slave channel q (q = 3, 7) in combination. The
TCRp of slave channel p operates in the up and down count mode, and counts the duty. TCRp loads the value of
TCRp loads the value of TDRp again when INTTMn is generated in an up status of the master channel. Similar
TCRq of slave channels 3, 7 operates in the one-count mode, and counts the dead time.
TCRq loads the value of TDRq and counts down by using count start timing and INTTMp of slave channels 2, 6 as
A triangular wave modulation PWM waveform with dead time is output by changing TOp and TOq by the count
Note that the active level of TOp and TOq can be changed by setting the TLS2, TLS3, TLS6, and TLS7 bits of the
The set condition of TOp (TOLp = 0) is the generation of INTTMq by the operation of slave channels 3, 7, which
The set condition of TOq (TOLq = 1) is the generation of INTTMp while the TCRp register counts down. The reset
If the set conditions and reset conditions of TOp and TOq conflict, the set conditions take precedence.
The PWM waveform with dead time can be switched between positive and negative phases for slave channels 2, 6
Cautions 1. TDRn of master channel n must be rewritten during an up status period of slave channels 2, 6
It is also possible to specify whether to add dead time to the positive logic output or the inverted logic output by
2. TSn, TSp, or TSq cannot be set to “1” (forcible restart) while TEn = 1, TEp = 1, or TEq = 1. If
(The count status is judged by CSF (TSRp register) of the slave channel or the TOn output
level of the master channel). When the value of TDRn is rewritten during a down status
period, the periods of the down status and up status differ and an expected waveform cannot
be output, because the value of TDRn of the rewritten master channel becomes valid at the
next period.
TSn, TSp, or TSq is set to “1” while TEn = 1, TEp = 1, or TEq = 1, the counter value (TCRn,
TCRp, or TCRq) will be illegal and TOn, TOp, or TOq will not be able to output the expected
waveform.