HD64F2318VTE25 Renesas Electronics America, HD64F2318VTE25 Datasheet - Page 503

IC H8S MCU FLASH 256K 100-QFP

HD64F2318VTE25

Manufacturer Part Number
HD64F2318VTE25
Description
IC H8S MCU FLASH 256K 100-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheets

Specifications of HD64F2318VTE25

Core Processor
H8S/2000
Core Size
16-Bit
Speed
25MHz
Connectivity
SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
71
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Serial data reception (asynchronous mode): Figure 12.7 shows a sample flowchart for serial
reception.
The following procedure should be used for serial data reception.
No
No
Read receive data in RDR, and
clear RDRF flag in SSR to 0
PER ∨ FER ∨ ORER = 1?
Read RDRF flag in SSR
Clear RE bit in SCR to 0
Read ORER, PER, and
All data received?
FER flags in SSR
Start of reception
Figure 12.7 Sample Serial Reception Flowchart
Initialization
RDRF = 1?
<End>
Yes
Yes
No
(Continued on next page)
Error handling
Yes
[1]
[2]
[4]
[5]
Section 12 Serial Communication Interface (SCI)
[3]
Rev.7.00 Feb. 14, 2007 page 469 of 1108
[1]
[2] [3]
[4]
[5]
SCI initialization:
The RxD pin is automatically
designated as the receive data
input pin.
break detection:
If a receive error occurs, read the
ORER, PER, and FER flags in
SSR to identify the error. After
performing the appropriate error
processing, ensure that the
ORER, PER, and FER flags are
all cleared to 0. Reception cannot
be resumed if any of these flags
are set to 1. In the case of a
framing error, a break can be
detected by reading the value of
the input port corresponding to
the RxD pin.
SCI status check and receive
data read :
Read SSR and check that RDRF
= 1, then read the receive data in
RDR and clear the RDRF flag to
0. Transition of the RDRF flag
from 0 to 1 can also be identified
by an RXI interrupt.
Serial reception continuation
procedure:
To continue serial reception,
before the stop bit for the current
frame is received, read the
RDRF flag, read RDR, and clear
the RDRF flag to 0. The RDRF
flag is cleared automatically
when the DTC is activated by an
RXI interrupt and the RDR value
is read.
Receive error handling and
REJ09B0089-0700