HD64F2318VTE25 Renesas Electronics America, HD64F2318VTE25 Datasheet - Page 99

IC H8S MCU FLASH 256K 100-QFP

HD64F2318VTE25

Manufacturer Part Number
HD64F2318VTE25
Description
IC H8S MCU FLASH 256K 100-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheets

Specifications of HD64F2318VTE25

Core Processor
H8S/2000
Core Size
16-Bit
Speed
25MHz
Connectivity
SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
71
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Section 2 CPU
(2) Reset Exception Handling
After the RES pin has gone low and the reset state has been entered, when RES goes high again,
reset exception handling starts. When reset exception handling starts the CPU fetches a start
address (vector) from the exception vector table and starts program execution from that address.
All interrupts, including NMI, are disabled during reset exception handling and after it ends.
(3) Traces
Traces are enabled only in interrupt control mode 2. Trace mode is entered when the T bit of EXR
is set to 1. When trace mode is established, trace exception handling starts at the end of each
instruction.
At the end of a trace exception-handling sequence, the T bit of EXR is cleared to 0 and trace mode
is cleared. Interrupt masks are not affected.
The T bit saved on the stack retains its value of 1, and when the RTE instruction is executed to
return from the trace exception-handling routine, trace mode is entered again. Trace exception-
handling is not executed at the end of the RTE instruction.
Trace mode is not entered in interrupt control mode 0, regardless of the state of the T bit.
(4) Interrupt Exception Handling and Trap Instruction Exception Handling
When interrupt or trap-instruction exception handling begins, the CPU references the stack pointer
(ER7) and pushes the program counter and other control registers onto the stack. Next, the CPU
alters the settings of the interrupt mask bits in the control registers. Then the CPU fetches a start
address (vector) from the exception vector table and program execution starts from that start
address.
Figure 2.13 shows the stack after exception handling ends.
Rev.7.00 Feb. 14, 2007 page 65 of 1108
REJ09B0089-0700