HD64F2318VTE25 Renesas Electronics America, HD64F2318VTE25 Datasheet - Page 505

IC H8S MCU FLASH 256K 100-QFP

HD64F2318VTE25

Manufacturer Part Number
HD64F2318VTE25
Description
IC H8S MCU FLASH 256K 100-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheets

Specifications of HD64F2318VTE25

Core Processor
H8S/2000
Core Size
16-Bit
Speed
25MHz
Connectivity
SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
71
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
In serial reception, the SCI operates as described below.
[1] The SCI monitors the communication line, and if a 0 stop bit is detected, performs internal
[2] The received data is stored in RSR in LSB-to-MSB order.
[3] The parity bit and stop bit are received.
Note: * Subsequent receive operations cannot be performed when a receive error has occurred.
[4] If the RIE bit in SCR is set to 1 when the RDRF flag changes to 1, a receive-data-full interrupt
synchronization and starts reception.
After receiving these bits, the SCI carries out the following checks.
[a] Parity check:
[b] Stop bit check:
[c] Status check:
If all the above checks are passed, the RDRF flag is set to 1, and the receive data is stored in
RDR.
If a receive error * is detected in the error check, the operation is as shown in table 12.11.
(RXI) request is generated.
Also, if the RIE bit in SCR is set to 1 when the ORER, PER, or FER flag changes to 1, a
receive-error interrupt (ERI) request is generated.
The SCI checks whether the number of 1 bits in the receive data agrees with the parity
(even or odd) set in the O/E bit in SMR.
The SCI checks whether the stop bit is 1.
If there are two stop bits, only the first is checked.
The SCI checks whether the RDRF flag is 0, indicating that the receive data can be
transferred from RSR to RDR.
Also note that the RDRF flag is not set to 1 in reception, and so the error flags must be
cleared to 0.
Section 12 Serial Communication Interface (SCI)
Rev.7.00 Feb. 14, 2007 page 471 of 1108
REJ09B0089-0700