HD64F2318VTE25 Renesas Electronics America, HD64F2318VTE25 Datasheet - Page 801

IC H8S MCU FLASH 256K 100-QFP

HD64F2318VTE25

Manufacturer Part Number
HD64F2318VTE25
Description
IC H8S MCU FLASH 256K 100-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheets

Specifications of HD64F2318VTE25

Core Processor
H8S/2000
Core Size
16-Bit
Speed
25MHz
Connectivity
SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
71
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
(3) Operating frequency error
Operating frequency is calculated from the received value of the input frequency and the
multiplication or division ratio. The input frequency is input to the LSI and the LSI is operated at
the operating frequency. The expression is given below.
The calculated operating frequency should be checked to ensure that it is within the range of
minimum to maximum frequencies which are available with the clock modes of the specified
device. When it is out of this range, an operating frequency error is generated.
(4) Bit rate
Peripheral operating clock (φ), bit rate (B), clock select (CKS) in the serial mode register (SMR).
The error as calculated by the method below is checked to ensure that it is less than 4%. When it
is 4% or more, a bit-rate selection error is generated.
When the new bit rate is selectable, the rate will be set in the register after sending ACK in
response. The host will send an ACK with the new bit rate for confirmation and the boot program
will response with that rate.
Confirmation
• Confirmation, H'06, (1 byte): Confirmation of a new bit rate
Response
• Response, H'06, (1 byte): Response to confirmation of a new bit rate
The sequence of new bit-rate selection is shown in figure 17.85.
Operating frequency = Input frequency × Multiplication ratio , or
Operating frequency = Input frequency ÷ Division ratio
Error (%) = {[
H'06
H'06
(N+1) * B * 64 * 2
φ * 10
6
(2*n−1)
] − 1} * 100
Rev.7.00 Feb. 14, 2007 page 767 of 1108
REJ09B0089-0700
Section 17 ROM