BMSKTOPASA900(DCE) Toshiba, BMSKTOPASA900(DCE) Datasheet - Page 588

KIT STARTER TMPA900 USB JTAG

BMSKTOPASA900(DCE)

Manufacturer Part Number
BMSKTOPASA900(DCE)
Description
KIT STARTER TMPA900 USB JTAG
Manufacturer
Toshiba
Series
TOPASr
Type
MCUr
Datasheets

Specifications of BMSKTOPASA900(DCE)

Contents
Evaluation Board, Cable(s), Software and Documentation
For Use With/related Products
TMPA900CMXBG
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
[31:16]
[15]
[14:13]
[12]
[11]
[10:0]
Bit
tx_0data
dset
max_pkt[10:0]
[Description]
a. <tx_0data>
b. <dset>
c.
Note 1: The initial value of dset (bit 12) after reset_x is 1 when the EPx is a transmit endpoint, while it is 0 when the
Note 2: The initial value of dset (bit 12) after USB_RESET is 1 when the EPx is a transmit endpoint, while it is "Retain"
Note 3: Since the register structure is identical for all EPs through EP1 and EP3, only EP1 is described here.
Note: For details, refer to section 3.16.4.2 “Appendix B About Setting an Odd Number of Bytes as MaxPacketSize”.
Symbol
When the “EP1_TX_0DATA” command is issued to EP1 by Command register or
Zero-Length data has been set at Endpoint-I/F, this bit will be set to 1. It will be cleared to
0 after the Zero-Length data has been transmitted.
Indicates the status of EP1_FIFO.
0y0: No valid data exists
0y1: Valid data exists
<max_pkt[10:0]>
Sets MaxPacketSize of EP1.
Set this when configuring the endpoint when Set_Configuration and Set_Interface are
received.
Set an even number for a transmit endpoint. On USB, when MaxPacketSize of a transmit
endpoint is an odd number, set an even number to max_pkt and make the odd number of
accesses to the endpoint. (For instance, set 1024 to max_pkt when the MaxPacketSize
should be 1023 bytes.)
(5) EP1 Control/Status Registers
1.
Bit
EPx is a receive endpoint.
when the EPx is a receive endpoint.
Addresses of registers for EP2 and EP3 can be confirmed in the register map.
UD2EP1MSZ (EP1_MaxPacketSize register)
RO
RO
R/W
Type
Undefined
0y0
Undefined
Note 1,Note 2
Undefined
0y00000000000
(-)(-)(-)(-)(-)(-)
(-)(-)(-)(-)(-)
TENTATIVE
Reset
Value
TMPA900CM- 587
Read as undefined. Write as zero.
When the "EP1_TX_0DATA" command is issued to EP1 by
Command register or Zero-Length data has been set at
Endpoint-I/F, this bit will be set to 1. It will be cleared to 0 after
the Zero-Length data has been transmitted.
Read as undefined. Write as zero.
Indicates the status of EP1_FIFO.
0y0: No valid data exists
0y1: Valid data exists
Read as undefined. Write as zero.
Sets MaxPacketSize of EP1.
Note: See 3.16.4.2 Appendix B About Setting an Odd Number
of Bytes as MaxPacketSize for more information.
Address = (0xF440_0000) + (0x0240)
Description
TMPA900CM
2009-10-14

Related parts for BMSKTOPASA900(DCE)