BMSKTOPASA900(DCE) Toshiba, BMSKTOPASA900(DCE) Datasheet - Page 808

KIT STARTER TMPA900 USB JTAG

BMSKTOPASA900(DCE)

Manufacturer Part Number
BMSKTOPASA900(DCE)
Description
KIT STARTER TMPA900 USB JTAG
Manufacturer
Toshiba
Series
TOPASr
Type
MCUr
Datasheets

Specifications of BMSKTOPASA900(DCE)

Contents
Evaluation Board, Cable(s), Software and Documentation
For Use With/related Products
TMPA900CMXBG
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3. ADMOD2 (AD mode control register 2)
[31:8]
[7]
[6]
[5]
[4:3]
[2:0]
Bit
[Description]
a. <EOCFHP>
b. <ADBFHP>
c. <HPADCE>
d. <HPADCH[2:0]>
R/W : Read/Write RO : Read Only WO : Write Only
Note: As read this register, <EOCFHP> is clear to 0.
Note: Always read as 0 when read.
Used to set the top-priority AD conversion end flag.
0y0: Before conversion or being converted
0y1: End
Used to set the top-priority AD conversion BUSY flag.
0y0: Conversion stop
0y1: Being converted
Controls the start of top-priority AD conversion.
0y0: Don't care
0y1: Conversion start
Analog input channel select during top-priority conversion
0y000: AN0 0y010: AN2 0y100: AN4 0y110: AN6
0y001: AN1 0y011: AN3 0y101: AN5 0y111: AN7
EOCFHP(Note)
ADBFHP
HPADCE
HPADCH[2:0]
Symbol
Bit
RO
RO
R/W
R/W
R/W
Type
0y0
0y00
Undefined
0y0
0y0
0y000
TENTATIVE
Reset
Value
TMPA900CM- 807
Read as undefined. Write as zero.
Top-priority AD conversion end flag
Read:
Write:
Top-priority AD conversion BUSY flag
Read:
Write:
Top-priority AD conversion start
0y0: Don't care
0y1: Conversion start. Always read as 0 when read.
Always write as 0.
Analog input channel select during top-priority conversion
0y000: AN0, 0y010: AN2, 0y100: AN4, 0y110: AN6
0y001: AN1, 0y011: AN3, 0y101: AN5, 0y111: AN7
0y0: Before conversion or being converted
0y1: End
Invalid
0y0: Conversion stop
0y1: Being converted
Invalid
Address = (0xF008_0000) + (0x0058)
Description
TMPA900CM
2009-10-14

Related parts for BMSKTOPASA900(DCE)