BMSKTOPASA900(DCE) Toshiba, BMSKTOPASA900(DCE) Datasheet - Page 821

KIT STARTER TMPA900 USB JTAG

BMSKTOPASA900(DCE)

Manufacturer Part Number
BMSKTOPASA900(DCE)
Description
KIT STARTER TMPA900 USB JTAG
Manufacturer
Toshiba
Series
TOPASr
Type
MCUr
Datasheets

Specifications of BMSKTOPASA900(DCE)

Contents
Evaluation Board, Cable(s), Software and Documentation
For Use With/related Products
TMPA900CMXBG
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3.24.2.4 AD Conversion Modes and AD Conversion End Interrupt
started, ADMOD0<ADBFN> is set to 1. When a specified AD conversion ends, the
Normal AD conversion end interrupt is generated, ADMOD0<EOCFN> is set 1 , shows
the end of the AD conversion sequence.
conversion, selection is available by setting ADMOD0<REPEAT and SCAN>. As for
top-priority AD conversion, only single conversion mode by channel fix mode is
available.
(1) Normal AD conversion
a. Channel-fix single conversion mode
b. Channel-scan single conversion mode
c. Channel-fix repeat conversion mode
a. Channel-fix single conversion mode
b. Channel-scan single conversion mode
c. Channel-fix repeat conversion mode
d. Channel-scan repeat conversion mode
To select operation modes, use ADMOD0<REPEAT, SCAN>. After AD conversion is
For AD conversion, the following four operation modes are provided: For normal AD
conversion mode.
conversion ends, ADMOD0<EOCFN> is set to 1, generating Normal AD
conversion End interrupt request. <EOCFN> is cleared to 0 only by being read.
conversion mode.
After scan conversion ends, ADMOD0<EOCFN> is set to 1, generating Normal
AD conversion End interrupt request. <EOCFN> is cleared to 0 only by being
read.
conversion mode.
conversion ends, ADMOD0<EOCFN> is set to 1. The timing of Normal AD
conversion End interrupt request generation can be selected by setting ADMOD0
<ITM>. The timing of <EOCFN> being set is also linked to the interrupt timing.
ends. In this case, conversion results are always stored into the storage register of
ADREGxH/L. At the point of storage, <EOCFN> is set to 1.
end. In this case, conversion results are stored into the storage registers of
ADREG0H/L to ADREG3H/L one after another. After stored into ADREG3,
<EOCFN> is set to 1, restarting storage from ADREG0. <EOCFN> is cleared to 0
only by being read.
Setting ADMOD0 <REPEAT, SCAN> to 0y00 selects the channel-fix single
This mode performs a conversion only one time at one channel selected. After
Setting ADMOD0 <REPEAT, SCAN> to 0y01 selects the channel-scan single
This mode performs a conversion only one time at each scan channel selected.
Setting ADMOD0<REPEAT, SCAN> to 0y10 selects the channel-fix repeat
This mode performs a conversion at one channel selected repeatedly. After
ADMOD0<EOCFN> is cleared to 0 only by being read.
Setting <ITM> to 0 generates an interrupt request each time an AD conversion
Setting <ITM> to 1 generates an interrupt request each time four AD conversions
TENTATIVE
TMPA900CM- 820
TMPA900CM
2009-10-14