Section 10 16-Bit Timer Pulse Unit (TPU)
Example of Synchronous Operation Setting Procedure
Figure 10.14 shows an example of the synchronous operation setting procedure.
Rev. 3.00 Sep 15, 2006 page 462 of 988
REJ09B0330-0300
<Synchronous presetting>
[1]
[2]
[3]
[4]
[5]
Synchronous presetting
Synchronous operation
Set synchronous
Set to 1 the SYNC bits in TSYR corresponding to the channels to be designated for synchronous
operation.
When the TCNT counter of any of the channels designated for synchronous operation is
written to, the same value is simultaneously written to the other TCNT counters.
Use bits CCLR2 to CCLR0 in TCR to specify TCNT clearing by input capture/output compare,
etc.
Use bits CCLR2 to CCLR0 in TCR to designate synchronous clearing for the counter clearing
source.
Set to 1 the CST bits in TSTR for the relevant channels, to start the count operation.
Set TCNT
operation
selection
Figure 10.14 Example of Synchronous Operation Setting Procedure
[1]
[2]
Synchronous clearing
<Counter clearing>
sourcegeneration
clearing source
Select counter
Start count
channel?
Clearing
Yes
No
[3]
[5]
<Synchronous clearing>
Set synchronous
counter clearing
Start count
[4]
[5]