Section 14 Smart Card Interface
Data Transfer Operation by DMAC or DTC
In smart card mode, as with the normal SCI, transfer can be carried out using the DMAC or DTC.
In a transmit operation, the TDRE flag is also set to 1 at the same time as the TEND flag in SSR,
and a TXI interrupt is generated. If the TXI request is designated beforehand as a DMAC or DTC
activation source, the DMAC or DTC will be activated by the TXI request, and transfer of the
transmit data will be carried out. The TDRE and TEND flags are automatically cleared to 0 when
data transfer is performed by the DMAC or DTC. In the event of an error, the SCI retransmits the
same data automatically. The TEND flag remains cleared to 0 during this time, and the DMAC is
not activated. Thus, the number of bytes specified by the SCI and DMAC are transmitted
automatically even in retransmission following an error. However, the ERS flag is not cleared
automatically when an error occurs, and so the RIE bit should be set to 1 beforehand so that an
ERI request will be generated in the event of an error, and the ERS flag will be cleared.
When performing transfer using the DMAC or DTC, it is essential to set and enable the DMAC or
DTC before carrying out SCI setting. For details of the DMAC and DTC setting procedures, see
section 7, DMA Controller (DMAC), and section 8, Data Transfer Controller (DTC).
In a receive operation, an RXI interrupt request is generated when the RDRF flag in SSR is set to
1. If the RXI request is designated beforehand as a DMAC or DTC activation source, the DMAC
or DTC will be activated by the RXI request, and transfer of the receive data will be carried out.
The RDRF flag is cleared to 0 automatically when data transfer is performed by the DMAC or
DTC. If an error occurs, an error flag is set but the RDRF flag is not. Consequently, the DMAC or
DTC is not activated, but instead, an ERI interrupt request is sent to the CPU. Therefore, the error
flag should be cleared.
Rev. 3.00 Sep 15, 2006 page 635 of 988