EP4SGX360FH29C3N Altera, EP4SGX360FH29C3N Datasheet - Page 114

no-image

EP4SGX360FH29C3N

Manufacturer Part Number
EP4SGX360FH29C3N
Description
IC STRATIX IV FPGA 360K 780HBGA
Manufacturer
Altera
Series
Stratix® IV GXr

Specifications of EP4SGX360FH29C3N

Number Of Logic Elements/cells
353600
Number Of Labs/clbs
14144
Total Ram Bits
22564
Number Of I /o
289
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
780-HBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4SGX360FH29C3N
Manufacturer:
Bussmann
Quantity:
40 000
Part Number:
EP4SGX360FH29C3N
Manufacturer:
ALTERA21
Quantity:
53
Part Number:
EP4SGX360FH29C3N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4SGX360FH29C3N
Manufacturer:
ALTERA
0
4–34
Table 4–9. DSP Block Dynamic Signals (Part 1 of 2)
Stratix IV Device Handbook Volume 1
output_round
chainout_round
output_saturate
chainout_saturate
signa
signb
Signal Name
DSP Block Control Signals
Use the rounding and saturation function just described in regular supported
multiplication operations, as specified in
accumulation-type operations, use the following convention:
The functionality of the round logic unit is in the format of:
Likewise, the functionality of the saturation logic unit is in the format of:
If you use both the rounding and saturation logic units for an accumulation type of
operation, the format is:
The Stratix IV DSP block is configured using a set of static and dynamic signals. You
can configure the DSP block dynamic signals. You can set the signals to toggle or not
toggle at run time.
Result = RND[
Result = SAT[
Result = SAT[RND[
Signed/unsigned control for all multipliers and adders.
Round control for the first stage round and saturation block.
Round control for the second stage round and saturation block.
Saturation control for the first stage round and saturation block for
Q-format multiply. If you enable both rounding and saturation,
saturation is done on the rounded result.
Saturation control for the second stage round and saturation block for
Q-format multiply. If you enable both rounding and saturation,
saturation is done on the rounded result.
signa for “multiplicand” input bus to dataa[17:0] to each
multiplier
signb for “multiplier” input bus datab[17:0] to each multiplier
signa = 1, signb = 1 for signed-signed multiplication
signa = 1, signb = 0 for signed-unsigned multiplication
signa = 0, signb = 1 for unsigned-signed multiplication
signa = 0, signb = 0 for unsigned-unsigned multiplication
output_round = 1 for rounding on multiply output
output_round = 0 for normal multiply output
chainout_round = 1 for rounding multiply output
chainout_round = 0 for normal multiply output
output_saturate = 1 for saturation support
output_saturate = 0 for no saturation support
chainout_saturate = 1 for saturation support
chainout_saturate = 0 for no saturation support
S
S
(A × B)], when used for an accumulation type of operation.
Table 4–9
(A × B)], when used for an accumulation type of operation.
S
(A × B)]]
lists the dynamic signals for the DSP block.
Function
Table 4–2 on page
Chapter 4: DSP Blocks in Stratix IV Devices
Stratix IV Operational Mode Descriptions
4–8. However, for
February 2011 Altera Corporation
Count
2
1
1
1
1

Related parts for EP4SGX360FH29C3N