EP4SGX360FH29C3N Altera, EP4SGX360FH29C3N Datasheet - Page 783

no-image

EP4SGX360FH29C3N

Manufacturer Part Number
EP4SGX360FH29C3N
Description
IC STRATIX IV FPGA 360K 780HBGA
Manufacturer
Altera
Series
Stratix® IV GXr

Specifications of EP4SGX360FH29C3N

Number Of Logic Elements/cells
353600
Number Of Labs/clbs
14144
Total Ram Bits
22564
Number Of I /o
289
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
780-HBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4SGX360FH29C3N
Manufacturer:
Bussmann
Quantity:
40 000
Part Number:
EP4SGX360FH29C3N
Manufacturer:
ALTERA21
Quantity:
53
Part Number:
EP4SGX360FH29C3N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4SGX360FH29C3N
Manufacturer:
ALTERA
0
Chapter 3: Configuring Multiple Protocols and Data Rates in Stratix IV Devices
Combining Transceiver Channels in Basic (PMA Direct) Configurations
Table 3–9. Basic (PMA Direct) ×1 and Non-Basic (PMA Direct) Configurations at the Same Data Rate for Example 6
February 2011 Altera Corporation
inst0
inst1
Instances
Basic (PMA Direct) ×1
(four channels)
Configuration
Combining Multiple Instances of Transmitter Only and Receiver Only
Configurations in Basic (PMA Direct) ×1 Mode
The Quartus II software allows you to combine instances of Transmitter Only and
Receiver Only configurations in Basic (PMA Direct) ×1 mode.
You can also combine Transmitter Only instances in non-Basic (PMA Direct) ×1
configuration (non-bonded only) and the Receiver Only instance in Basic (PMA
Direct) configurations (and vice versa) in the same physical channel. The combination
requirements of the instances in Basic (PMA Direct) ×1 configuration are similar to
that of non-Basic (PMA Direct) configuration. For more information, refer to the
“Combining Transmitter Channel and Receiver Channel Instances” on page
Combining Channels Configured in Basic (PMA Direct) ×1 with Non-Basic
(PMA Direct) Modes
You can combine a transceiver channel instance configured in Basic (PMA Direct) ×1
configuration with instances set up in non-Basic (PMA Direct) configurations (for
example, GIGE and SDI within the same transceiver block).
If the CMU PLL configuration for the Basic (PMA Direct) ×1 configuration and the
non-Basic (PMA Direct) configuration instances meet the requirements specified in
“Multiple Channels Sharing a CMU PLL” on page 3–5
Combine Channels” on page
these two instances. In addition, to share the same CMU PLL between the two
instances, you cannot enable the channel reconfiguration option in the instance setup
in non-Basic (PMA Direct) configuration.
Example 6
Consider the example design listed in
non-Basic (PMA Direct) configurations at the same data rate.
GIGE
Data Rate (Gbps)
CMU PLL Base
1.25
1.25
3–3, the Quartus II software uses a single CMU PLL for
Effective Data Rate (Gbps)
Table 3–9
Transmitter Channel
1.25
1.25
for Basic (PMA Direct) ×1 and
Stratix IV Device Handbook Volume 2: Transceivers
and
“General Requirements to
Input Reference Clock
(assume refclk0)
Frequency (MHz)
Same as inst0
125
3–11.
3–29

Related parts for EP4SGX360FH29C3N