EP4SGX360FH29C3N Altera, EP4SGX360FH29C3N Datasheet - Page 415

no-image

EP4SGX360FH29C3N

Manufacturer Part Number
EP4SGX360FH29C3N
Description
IC STRATIX IV FPGA 360K 780HBGA
Manufacturer
Altera
Series
Stratix® IV GXr

Specifications of EP4SGX360FH29C3N

Number Of Logic Elements/cells
353600
Number Of Labs/clbs
14144
Total Ram Bits
22564
Number Of I /o
289
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
780-HBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4SGX360FH29C3N
Manufacturer:
Bussmann
Quantity:
40 000
Part Number:
EP4SGX360FH29C3N
Manufacturer:
ALTERA21
Quantity:
53
Part Number:
EP4SGX360FH29C3N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4SGX360FH29C3N
Manufacturer:
ALTERA
0
Chapter 11: SEU Mitigation in Stratix IV Devices
Error Detection Timing
February 2011 Altera Corporation
1
You can set a lower clock frequency by specifying a division factor in the Quartus II
software (refer to
in which n is between 1 and 8. The divisor ranges from 2 through 256. Refer to
Equation
Equation 11–1.
The error detection frequency reflects the frequency of the error detection process for
a frame because the CRC calculation in the Stratix IV device is done on a per-frame
basis.
You must monitor the error message to avoid missing information in the error
message register. The error message register is updated whenever an error occurs. The
minimum interval time between each update for the error message register depends
on the device and the error detection clock frequency.
Table 11–6
error message register for Stratix IV devices.
Table 11–6. Minimum Update Interval for Error Message Register
CRC calculation time for the error detection circuitry to check from the first until the
last frame depends on the device and the error detection clock frequency.
Note to
(1) These timing numbers are preliminary.
Table
11–1.
lists the estimated minimum interval time between each update for the
11–6:
EP4SGX110
EP4SGX180
EP4SGX230
EP4SGX290
EP4SGX360
EP4SGX530
EP4S100G2
EP4S100G3
EP4S100G4
EP4S100G5
EP4SGX70
EP4S40G2
EP4S40G5
EP4SE230
EP4SE360
EP4SE530
EP4SE820
“Software Support” on page
Device
error detection frequency
11–10). The divisor is a power of two,
=
100 MHz
----------------------- -
2
n
Timing Interval (μs)
Stratix IV Device Handbook Volume 1
(Note 1)
13.8
13.8
19.8
19.8
21.8
21.8
26.8
19.8
21.8
26.8
33.8
19.8
26.8
19.8
26.8
26.8
26.8
11–9

Related parts for EP4SGX360FH29C3N