Section 14 A/D Converter
14.4
The A/D converter operates by successive approximations with 10-bit resolution. It has two
operating modes: single mode and scan mode. In single mode, conversion is performed once on
one specified channel, then ends. In scan mode, A/D conversion continues on one or more
specified channels until the ADST bit is cleared to 0.
14.4.1
Single mode, should be selected when only one A/D conversion on one channel is required. Single
mode is selected for A/D0 by setting the ADM1 and ADM0 bits in A/D control/status register 0
(ADSCR0) to 00, and for A/D1 by clearing the SCAN mode bit in ADCSR1 to 0. When the
ADST bit (in ADCR0 for A/D0, or in ADCSR1 for A/D1) is set to 1, A/D conversion is started in
single mode.
The ADST bit remains set to 1 during A/D conversion, and is automatically cleared to 0 when
conversion ends.
When conversion ends, the ADF flag in ADCSR is set to 1. If the ADIE bit in ADCSR is also 1,
an ADI interrupt is requested. To clear the ADF flag, first read ADF when set to 1, then write 0 in
ADF. If the DMAC is activated by the ADI interrupt, ADF is cleared automatically.
An example of the operation when analog input channel 1 (AN1) is selected and A/D conversion
is performed in single mode is described next. Figure 14.3 shows a timing diagram for this
example.
1. Single mode is selected (ADM1 = ADM0 = 0), input channel AN1 is selected (CH3 = CH2 =
2. When A/D conversion is completed, the result is transferred to ADDR1. At the same time the
3. Since ADF = 1 and ADIE = 1, an ADI interrupt is requested.
4. The A/D interrupt handling routine is started.
5. The routine reads ADF set to 1, then writes 0 in ADF.
6. The routine reads and processes the conversion result (ADDR1).
7. Execution of the A/D interrupt handling routine ends. After this, if the ADST bit is set to 1,
Rev. 5.00 Jan 06, 2006 page 448 of 818
REJ09B0273-0500
CH1 = 0, CH0 = 1), the A/D interrupt is enabled (ADIE = 1), and A/D conversion is started
(ADST = 1).
ADF flag is set to 1, the ADST bit is cleared to 0, and the A/D converter becomes idle.
A/D conversion starts again and steps 2 to 7 are repeated.
Operation
Single Mode