DF2345TE20 Renesas Electronics America, DF2345TE20 Datasheet - Page 484

MCU 5V 128K 100-TQFP

DF2345TE20

Manufacturer Part Number
DF2345TE20
Description
MCU 5V 128K 100-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheet

Specifications of DF2345TE20

Core Processor
H8S/2000
Core Size
16-Bit
Speed
20MHz
Connectivity
SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
71
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Other names
HD64F2345TE20
HD64F2345TE20

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF2345TE20V
Manufacturer:
Renesas
Quantity:
222
Part Number:
DF2345TE20V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 12 Serial Communication Interface (SCI)
Rev. 4.00 Feb 15, 2006 page 458 of 900
REJ09B0291-0400
No
No
No
Figure 12.12 Sample Multiprocessor Serial Reception Flowchart
Read ORER and FER flags in SSR
Read ORER and FER flags in SSR
Read receive data in RDR
Read receive data in RDR
Clear RE bit in SCR to 0
Read RDRF flag in SSR
Read RDRF flag in SSR
Read MPIE bit in SCR
All data received?
FER
This station's ID?
FER
Start reception
Initialization
RDRF = 1
RDRF = 1
<End>
ORER = 1
ORER = 1
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
Error processing
[4]
[3]
[1]
[2]
(Continued on
next page)
[5]
[1]
[2]
[3]
[4]
[5]
SCI initialization:
The RxD pin is automatically
designated as the receive data
input pin.
ID reception cycle:
Set the MPIE bit in SCR to 1.
SCI status check, ID reception
and comparison:
Read SSR and check that the
RDRF flag is set to 1, then read
the receive data in RDR and
compare it with this station’s ID.
If the data is not this station’s ID,
set the MPIE bit to 1 again, and
clear the RDRF flag to 0.
If the data is this station’s ID,
clear the RDRF flag to 0.
SCI status check and data
reception:
Read SSR and check that the
RDRF flag is set to 1, then read
the data in RDR.
Receive error processing and
break detection:
If a receive error occurs, read the
ORER and FER flags in SSR to
identify the error. After
performing the appropriate error
processing, ensure that the
ORER and FER flags are all
cleared to 0.
Reception cannot be resumed if
either of these flags is set to 1.
In the case of a framing error, a
break can be detected by reading
the RxD pin value.

Related parts for DF2345TE20