MC912DG128A Motorola, MC912DG128A Datasheet - Page 132

no-image

MC912DG128A

Manufacturer Part Number
MC912DG128A
Description
Microcontrollers
Manufacturer
Motorola
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC912DG128ACPV
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC912DG128ACPV
Manufacturer:
FREE
Quantity:
20 000
Part Number:
MC912DG128ACPV 5K91D
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MC912DG128ACPVE
Manufacturer:
MICREL
Quantity:
9 982
Part Number:
MC912DG128ACPVE
Manufacturer:
FREESCALE
Quantity:
1 200
Part Number:
MC912DG128ACPVE
Manufacturer:
FREESCALE
Quantity:
1 970
Part Number:
MC912DG128ACPVE
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC912DG128ACPVE
Manufacturer:
FREESCALE
Quantity:
1 970
Part Number:
MC912DG128ACPVER
Manufacturer:
STM
Quantity:
1 244
Part Number:
MC912DG128ACPVER
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC912DG128AMPV
Manufacturer:
AD
Quantity:
16
Part Number:
MC912DG128AMPVE
Manufacturer:
FREESCALE
Quantity:
2 902
Part Number:
MC912DG128AVPVE
Quantity:
36
Key Wake-Up Input Filter
I/O Ports With Key Wake-Up
MC68HC912DT128A Rev 2.0
132
The KWU input signals are filtered by a digital filter which is active only
during STOP mode.
The purpose of the filter is to prevent single pulses shorter than a
specified value from waking the part from STOP.
The filter is composed of an internal oscillator and a majority voting logic.
The filter oscillator starts the oscillation by detecting a triggering edge on
an input if the corresponding interrupt enable bit is set.
The majority voting logic takes three samples of an asserted input pin at
each filter oscillator period and if two samples are taken at the triggering
level, the filter recognizes a valid triggering level and sets the
corresponding interrupt flag. In this way the majority voting logic rejects
the short non-triggering state between two incoming triggering pulses.
As the filter is shared with all KWU inputs, the filter considers any pulse
coming from any input pin for which the corresponding interrupt enable
bit is set.
The timing specification is given for a single pulse. The time interval
between the triggering edges of two following pulses should be greater
than the tKWSP in order to be considered as a single pulse by the filter.
If this time interval is shorter than tKWSP, the majority voting logic may
treat the two consecutive pulses as a single valid pulse.
The filter is shared by all the KWU pins. Hence any valid triggering level
on any KWU pin is seen by the filter. The timing specification applies to
the input of the filter.
I/O Ports With Key Wake-Up
MOTOROLA
6-kwu

Related parts for MC912DG128A