UPD78F1009GB-GAH-AX Renesas Electronics America, UPD78F1009GB-GAH-AX Datasheet - Page 827

no-image

UPD78F1009GB-GAH-AX

Manufacturer Part Number
UPD78F1009GB-GAH-AX
Description
MCU 16BIT 78K0R/KX3-L 64-LQFP
Manufacturer
Renesas Electronics America
Series
78K0R/Kx3-Lr
Datasheet

Specifications of UPD78F1009GB-GAH-AX

Core Processor
78K/0R
Core Size
16-Bit
Speed
20MHz
Connectivity
3-Wire SIO, I²C, LIN, UART/USART
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
50
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Ram Size
3K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD78F1009GB-GAH-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
78K0R/Kx3-L
R01UH0106EJ0300 Rev.3.00
Oct 01, 2010
The meanings of <1> to <6> in (1) Start condition ~ address ~ data in Figure 15-32 are explained below.
Note If the transmitted address does not match the address of the slave device, the slave device does not return
Remark <1> to <15> in Figure 15-32 represent the entire procedure for communicating data using the I
<1> The start condition trigger is set by the master device (STT = 1) and a start condition (SDA0 = 0 and SCL0
<2> The master device writes the address + W (transmission) to the IICA shift register (IICA) and transmits the
<3> If the address received matches the address of a slave device
<4> The master device issues an interrupt (INTIICA: end of address transmission) at the falling edge of the 9th
<5> The master device writes the data to transmit to the IICA register and releases the wait status that it set by
<6> If the slave device releases the wait status (WREL = 1), the master device starts transferring data to the
an ACK to the master device (NACK: SDA0 = 1). The slave device also does not issue the INTIICA interrupt
(address match) and does not set a wait status. The master device, however, issues the INTIICA interrupt
(end of address transmission) regardless of whether it receives an ACK or NACK.
= 1) is generated once the bus data line goes low (SDA0 = 0). When the start condition is subsequently
detected, the master device enters the master device communication status (MSTS = 1). The master
device is ready to communicate once the bus clock line goes low (SCL0 = 0) after the hold time has
elapsed.
slave address.
hardware to the master device. The ACK is detected by the master device (ACKD = 1) at the rising edge of
the 9th clock.
clock, and the slave device whose address matched the transmitted slave address also issues an interrupt
(INTIICA: address match). The master device and slave device also set a wait status (SCL0 = 0)
the addresses match.
the master device.
slave device.
Figure 15-32 (1) Start condition ~ address ~ data shows the processing from <1> to <6>, Figure 15-32
(2) Address ~ data ~ data shows the processing from <3> to <10>, and Figure 15-32 (3) Data ~ data ~
stop condition shows the processing from <7> to <15>.
CHAPTER 15 SERIAL INTERFACE IICA
Note
, that slave device sends an ACK by
2
C bus.
Note
when
827