DS3163 Maxim Integrated Products, DS3163 Datasheet - Page 168

IC TRPL ATM/PACKET PHY 400-PBGA

DS3163

Manufacturer Part Number
DS3163
Description
IC TRPL ATM/PACKET PHY 400-PBGA
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS3163

Applications
*
Mounting Type
Surface Mount
Package / Case
400-BGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS3163
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS3163N
Manufacturer:
Maxim Integrated
Quantity:
10 000
Table 10-33. M23 DS3 Frame Overhead Bit Definitions
X
P
M
F
C
C
10.10.6.2 Transmit M23 DS3 Frame Generation
M23 DS3 frame generation receives the incoming payload data stream, and overwrites the entire DS3 overhead bit
locations.
The multiframe alignment bits (M
respectively.
The subframe alignment bits (F
respectively.
The X-bits (X
programmable (automatic, 1, or 0). If the T3.TCR.ARDID is one then the T3.TCR.TRDI register bit controls this bit.
If the RDI is generated automatically (T3.TCR.ARDID=0), the X-bits are set to zero when one or more of the
indicated alarm conditions is present, and set to one when all of the indicated alarm conditions are absent.
Automatically setting RDI on LOS, SEF, LOF, or AIS is individually programmable (on or off).
The P-bits (P
payload parity is calculated by performing modulo 2 addition of all of the payload bits after all frame processing has
been completed. P-bit generation is programmable (on or off). The P-bits will be generated if either P-bit generation
is enabled or frame generation is enabled.
If C-bit generation is enabled (T3.TCR.CBGE), the bit C
of the other C-bits (C
(C
Overhead insertion may still overwrite the C-bit time slots even if C-bit generation is disabled.
Once all of the DS3 overhead bits have been overwritten, the data stream is passed on to error insertion. If frame
generation is disabled, the incoming DS3 signal is passed on directly to error insertion. Frame generation is
programmable (on or off). Note: P-bit generation may still be performed even if frame generation is disabled.
10.10.6.3 Transmit M23 DS3 Error Insertion
Error insertion inserts various types of errors into the different DS3 overhead bits. The types of errors that can be
inserted are framing errors and P-bit parity errors.
The framing error insertion mode is programmable (F-bit, M-bit, SEF, or OOMF). An F-bit error is a single subframe
alignment bit (F
error in all the subframe alignment bits in a subframe (F
alignment bit (M
A P-bit parity error is generated by is inverting the value of the P-bits (P
error(s) can be inserted one error at a time, or continuously. The P-bit parity error insertion mode (single or
continuous) is programmable.
XY
1
1
11
X1
1
, X
, P
XY
, M
, C
) will be treated as payload data, and passed through. C-bit generation is programmable (on or off). Note:
2
2
2
X2
, and M
Bit
, and C
1
3
1
and P
X3
XY
1
, M
and X
) error. An M-bit error is a single multiframe alignment bit (M
2
Remote Defect Indication
(RDI)
Parity Bits
Multiframe Alignment Bits
Subframe Alignment Bits
Application Identification
Channel (AIC)
Stuff Control Bits for Tributary
#X
, or M
2
XY
) are both overwritten with the calculated payload parity from the previous DS3 frame. The
2
) are overwritten with zeros. If C-bit generation is disabled, then all of the C-bit timeslots
) are both overwritten with the Remote Defect Indicator (RDI). The RDI source is
3
) error in each of two consecutive DS3 frames.
Definition
X1
, F
1
X2
, M
, F
2
X3
, and M
, and F
X4
3
) are overwritten with the values zero, one, and zero (010)
) are overwritten with the values one, zero, zero, and one (1001)
11
X1
, F
is overwritten with an alternating one zero pattern, and all
X2
, F
X3
, and F
1
and P
X4
). An OOMF error is a single multiframe
1
, M
2
) in a single DS3 frame. P-bit parity
2
, or M
3
) error. An SEF error is an

Related parts for DS3163