DS3163 Maxim Integrated Products, DS3163 Datasheet - Page 269

IC TRPL ATM/PACKET PHY 400-PBGA

DS3163

Manufacturer Part Number
DS3163
Description
IC TRPL ATM/PACKET PHY 400-PBGA
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS3163

Applications
*
Mounting Type
Surface Mount
Package / Case
400-BGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS3163
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS3163N
Manufacturer:
Maxim Integrated
Quantity:
10 000
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
Bit #
Name
Default
Bits 7 to 0: Receive Trail Trace Identifier Data (RTD[7:0]) – These eight bits are the receive trail trace identifier
data. The receive trail trace identifier address will be incremented whenever these bits are read (when byte Fh is
read, the address will return to 0h).
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
Bit #
Name
Default
Bits 7 to 0: Expected Trail Trace Identifier Data (ETD[7:0]) – These eight bits are the expected trail trace
identifier data. The expected trail trace identifier address will be incremented whenever these bits are read or
written (when byte Fh is read or written, the address will return to 0h).
RTD7
ETD7
15
15
--
--
0
7
0
0
7
0
RTD6
ETD6
14
14
--
--
0
6
0
0
6
0
TT.RIR
Trail Trace Receive Identifier Register
(0,2,4,6)FCh
TT.EIR
Trail Trace Expected Identifier Register
(0,2,4,6)FEh
RTD5
ETD5
13
13
--
--
0
5
0
0
5
0
RTD4
ETD4
12
12
--
0
0
--
0
0
4
4
RTD3
ETD3
11
11
--
--
0
3
0
0
3
0
RTD2
ETD2
10
10
--
--
0
2
0
0
2
0
RTD1
ETD1
--
--
9
0
1
0
9
0
1
0
RTD0
ETD0
--
--
8
0
0
0
8
0
0
0

Related parts for DS3163