EP4SGX530HH35C2N Altera, EP4SGX530HH35C2N Datasheet - Page 389

IC STRATIX IV FPGA 530K 1152HBGA

EP4SGX530HH35C2N

Manufacturer Part Number
EP4SGX530HH35C2N
Description
IC STRATIX IV FPGA 530K 1152HBGA
Manufacturer
Altera
Series
Stratix® IV GXr

Specifications of EP4SGX530HH35C2N

Number Of Logic Elements/cells
531200
Number Of Labs/clbs
21248
Total Ram Bits
27376
Number Of I /o
564
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
1152-HBGA
Family Name
Stratix® IV
Number Of Logic Blocks/elements
531200
# Registers
424960
# I/os (max)
560
Process Technology
40nm
Operating Supply Voltage (typ)
900mV
Logic Cells
531200
Ram Bits
28033024
Operating Supply Voltage (min)
0.87V
Operating Supply Voltage (max)
0.93V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
1152
Package Type
FCHBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4SGX530HH35C2N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4SGX530HH35C2N
Manufacturer:
ALTERA
0
Part Number:
EP4SGX530HH35C2NAD
Manufacturer:
ALTERA
0
Part Number:
EP4SGX530HH35C2NAE
Manufacturer:
ALTERA
0
Chapter 10: Configuration, Design Security, and Remote System Upgrades in Stratix IV Devices
Remote System Upgrade Mode
April 2011 Altera Corporation
The factory image is user-designed and contains soft logic to:
Figure 10–24
configurations in remote update mode.
Figure 10–24. Transitions Between Configurations in Remote Update Mode
After power up or a configuration error, the factory configuration logic is loaded
automatically. The factory configuration also must specify whether to enable the user
watchdog timer for the application configuration and if enabled, to include the timer
setting information.
The user watchdog timer ensures that the application configuration is valid and
functional. The timer must be continually reset within a specific amount of time
during user mode operation of an application configuration. Only valid application
configurations contain the logic to reset the timer in user mode. This timer reset logic
must be part of a user-designed hardware and/or software health monitoring signal
that indicates error-free system operation. If the timer is not reset in a specific amount
of time; for example, the user application configuration detects a functional problem
or if the system hangs, the dedicated circuitry updates the remote system upgrade
status register, triggering the loading of the factory configuration.
Process any errors based on status information from the dedicated remote system
upgrade circuitry
Communicate with the remote host and receive new application configurations
and store this new configuration data in the local non-volatile memory device
Determine which application configuration is to be loaded into the Stratix IV
device
Enable or disable the user watchdog timer and load its time-out value (optional)
Instruct the dedicated remote system upgrade circuitry to initiate a
reconfiguration cycle
Configuration
Error
shows the transitions between the factory and application
Power Up
Configuration
(page 0)
Factory
Set Control Register
Set Control Register
Configuration Error
Configuration Error
and Reconfigure
and Reconfigure
Different Application
Different Application
Reload a
Reload a
Stratix IV Device Handbook Volume 1
Application 1
Configuration
Configuration
Application n
10–55

Related parts for EP4SGX530HH35C2N