EP4SGX530HH35C2N Altera, EP4SGX530HH35C2N Datasheet - Page 855

IC STRATIX IV FPGA 530K 1152HBGA

EP4SGX530HH35C2N

Manufacturer Part Number
EP4SGX530HH35C2N
Description
IC STRATIX IV FPGA 530K 1152HBGA
Manufacturer
Altera
Series
Stratix® IV GXr

Specifications of EP4SGX530HH35C2N

Number Of Logic Elements/cells
531200
Number Of Labs/clbs
21248
Total Ram Bits
27376
Number Of I /o
564
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
1152-HBGA
Family Name
Stratix® IV
Number Of Logic Blocks/elements
531200
# Registers
424960
# I/os (max)
560
Process Technology
40nm
Operating Supply Voltage (typ)
900mV
Logic Cells
531200
Ram Bits
28033024
Operating Supply Voltage (min)
0.87V
Operating Supply Voltage (max)
0.93V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
1152
Package Type
FCHBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4SGX530HH35C2N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4SGX530HH35C2N
Manufacturer:
ALTERA
0
Part Number:
EP4SGX530HH35C2NAD
Manufacturer:
ALTERA
0
Part Number:
EP4SGX530HH35C2NAE
Manufacturer:
ALTERA
0
Chapter 5: Dynamic Reconfiguration in Stratix IV Devices
Quartus II MegaWizard Plug-In Manager Interfaces to Support Dynamic Reconfiguration
February 2011 Altera Corporation
Logical Channel Addressing—Combination of Regular Transceiver Channels and PMA-Only
Channels
For a combination of regular transceiver channels and PMA-only channels, there must
be at least two different ALTGX instances connected to the same dynamic
reconfiguration controller. This is because you cannot have a combination of regular
transceiver channels and PMA-only channels within the same ALTGX instance.
Set the starting channel number in the first ALTGX Instance 1 to 0. If you have
configured ALTGX Instance 1 with regular transceiver channels, the logical channel
addresses of the remaining channels increment in steps of one.
Set the starting channel number of the following ALTGX Instance 2 as the next
multiple of four. If you have configured ALTGX Instance 2 with PMA-only channels,
the logical channel addresses of the remaining channels increment in steps of four.
Figure 5–41
number for multiple ALTGX instances controlled by a single dynamic reconfiguration
controller, where one ALTGX instance has PMA-only channels and the other ALTGX
instance has regular transceiver channels.
Table 5–18
channel address of both the PMA-only channels and regular transceiver channels is
set based on the starting channel number.
For more information, refer to
Table 5–4
channel in a Stratix IV device.
The maximum number of transceiver channels in the largest Stratix IV device is 48
(24 transceiver channels located in four transceiver blocks on the right side of the
device and 24 transceiver channels located in four transceiver blocks on the left side of
the device).
You can individually configure these 48 transceiver channels as 48 Transmitter only
and 48 Receiver only channels. You achieve this by using 48 Transmitter only ALTGX
instances and 48 Receiver only ALTGX instances in your design.
Highest Possible Logical Channel Address
lists the highest possible logical channel address assigned to a transceiver
in
in
“Example 1” on page 5–94
“Example 1” on page 5–94
“Example 1” on page
lists an example scenario where the logical
shows how to set the starting channel
Stratix IV Device Handbook Volume 2: Transceivers
5–94.
5–9