EP4SGX530HH35C2N Altera, EP4SGX530HH35C2N Datasheet - Page 758

IC STRATIX IV FPGA 530K 1152HBGA

EP4SGX530HH35C2N

Manufacturer Part Number
EP4SGX530HH35C2N
Description
IC STRATIX IV FPGA 530K 1152HBGA
Manufacturer
Altera
Series
Stratix® IV GXr

Specifications of EP4SGX530HH35C2N

Number Of Logic Elements/cells
531200
Number Of Labs/clbs
21248
Total Ram Bits
27376
Number Of I /o
564
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
1152-HBGA
Family Name
Stratix® IV
Number Of Logic Blocks/elements
531200
# Registers
424960
# I/os (max)
560
Process Technology
40nm
Operating Supply Voltage (typ)
900mV
Logic Cells
531200
Ram Bits
28033024
Operating Supply Voltage (min)
0.87V
Operating Supply Voltage (max)
0.93V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
1152
Package Type
FCHBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4SGX530HH35C2N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4SGX530HH35C2N
Manufacturer:
ALTERA
0
Part Number:
EP4SGX530HH35C2NAD
Manufacturer:
ALTERA
0
Part Number:
EP4SGX530HH35C2NAE
Manufacturer:
ALTERA
0
3–4
Stratix IV Device Handbook Volume 2: Transceivers
Control Signals
f
1
1
The Stratix IV GX and GT device provides you the option to select 2.5 V or 3.0 V for
the VCCA_L/R supply through the ALTGX MegaWizard Plug-In Manager. The
Stratix IV GT device only allows 3.3 V for the V
VCCA_L/R value for all the transceiver channel instances to enable the Quartus II
software to place them in the transceiver blocks on the same side of the device. For
example, if you have two ALTGX instances that you would like to place on the left
side transceiver banks GXBL0 and GXBL1, the VCCA_L/R values in the two ALTGX
instances must be the same.
The data rate of the transceiver channel is limited based on the V
selected.
For the data rate restrictions, refer to the
Devices
This section contains information about the gxb_powerdown, reconfig_fromgxb, and
reconfig_togxb ports.
gxb_powerdown Port
The gxb_powerdown port is an optional port that you can enable in the ALTGX
MegaWizard Plug-In Manager. If enabled, you must drive the gxb_powerdown port in
the ALTGX instances from the same logic or the same input pin to enable the
Quartus II software to assign them in the same transceiver block.
reconfig_fromgxb and reconfig_togxb Ports
In the ALTGX MegaWizard Plug-In Manager, the reconfig_fromgxb and
reconfig_togxb ports are enabled if you select one of the following options in the
Reconfig screen:
To combine multiple instances within the same transceiver block:
For example, consider that you want to place a Receiver only and Transmitter only
instance in the same transceiver block. For the Receiver only instance, the Quartus II
software automatically enables the reconfig_fromgxb port. For the Transmitter only
instance, you must select the options in the Reconfig screen (mentioned above) to
enable the reconfig_fromgxb port. In the design, connect these ports from the
Transmitter only and Receiver only instance to the same reconfig controller.
Analog Controls (VOD, Pre-emphasis, Manual Equalization, and EyeQ)
Enable Channel and Transmitter PLL reconfiguration
Offset cancellation for receiver channels (always enabled if the configuration is
Transmitter and Receiver or Receiver only)
The reconfig_fromgxb ports must be enabled in each instance AND
These ports must be connected to the same reconfig controller
chapter.
Chapter 3: Configuring Multiple Protocols and Data Rates in Stratix IV Devices
DC and Switching Characteristics for Stratix IV
CCA_L/R
General Requirements to Combine Channels
supply. You must set the same
February 2011 Altera Corporation
CCA_L/R
value