Specifications of SAF-C161U-LF V1.3

Core Processor
C166
Core Size
16-Bit
Speed
36MHz
Connectivity
EBI/EMI, SPI, UART/USART, USB
Peripherals
POR, PWM, WDT
Number Of I /o
56
Program Memory Type
ROMless
Ram Size
3K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
100-LFQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-
Data Converters
-
Other names
SAFC161ULFV1.3X
SAFC161ULFV13XP
SP000007502
Note: SYSCON2 is a security register. The security level is automatically set to write
Note: To be compatibile to Infineon’s C167CR / 167CS, the Power Down Control
Data Sheet
Bit
PDCON
RCS
SCS
CLKCON
CLKREL
CLKLOCK
protectection after execution of EINIT.
PDCON must be programmed to ’10’ (RTC = Off, Ports = On) during the
initialisation phase before the execution of EINIT instruction. The initial state after
reset is so defined that a reset does not interrupt the real time clock.
Clock State Control
Clock Signal Status Bit
Function
Power Down Control (during power down mode)
x0:
x1:
In power down mode, the RTC of the C161U is always off. Bit 5 of
SYSCON2 is don’t care.
RTC Clock Source (not affected by a reset)
0:
1:
SDD Clock Source (not affected by a reset)
Has to be set to ’0’.
00:
01:
10:
11:
Reload Counter Value for Slowdown Divider
0:
1:
RTC = Off,
RTC = Off,
RTC is switched to synchronous mode. The input is derived from
the CPU clock.
RTC is switched to asynchronous mode. The input is derived
from the RTC_REF_CLK (oscillator clock).
Running on configured basic frequency.
Running on slow down frequency, PLL ON.
Running on slow down frequency, PLL OFF.
Reserved. Do not use this combination.
Main oscillator is unstable or PLL is unlocked.
Main oscillator is stable and PLL is locked.
Ports = On (default after reset).
Ports = Off.
391
System Control Unit (CSCU)