MK30DN512ZVLK10 Freescale Semiconductor, MK30DN512ZVLK10 Datasheet - Page 454

no-image

MK30DN512ZVLK10

Manufacturer Part Number
MK30DN512ZVLK10
Description
ARM Microcontrollers - MCU KINETIS 512K SLCD
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MK30DN512ZVLK10

Core
ARM Cortex M4
Processor Series
K30
Data Bus Width
32 bit
Maximum Clock Frequency
50 MHz
Program Memory Size
512 KB
Data Ram Size
128 KB
On-chip Adc
Yes
Operating Supply Voltage
1.71 V to 3.6 V
Operating Temperature Range
- 40 C to + 105 C
Package / Case
LQFP-80
Mounting Style
SMD/SMT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MK30DN512ZVLK10
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Functional description
21.4 Functional description
21.4.1 eDMA basic data flow
The basic flow of a data transfer can be partitioned into three segments.
As shown in the following diagram, the first segment involves the channel activation:
454
BITER
14–0
Field
value extends to 15 bits in place of a link channel number. If the major loop is exhausted, this link
mechanism is suppressed in favor of the MAJORELINK channel linking.
NOTE: When the software loads the TCD, this field must be set equal to the corresponding CITER field.
0
1
Starting Major Iteration Count
As the transfer control descriptor is first loaded by software, this 9-bit (ELINK = 1) or 15-bit (ELINK = 0)
field must be equal to the value in the CITER field. As the major iteration count is exhausted, the contents
of this field are reloaded into the CITER field.
NOTE: When the software loads the TCD, this field must be set equal to the corresponding CITER field.
DMA_TCDn_BITER_ELINKNO field descriptions (continued)
The channel-to-channel linking is disabled
The channel-to-channel linking is enabled
Otherwise, a configuration error is reported. As the major iteration count is exhausted, the
contents of this field is reloaded into the CITER field.
Otherwise, a configuration error is reported. As the major iteration count is exhausted, the
contents of this field is reloaded into the CITER field. If the channel is configured to execute a
single service request, the initial values of BITER and CITER should be 0x0001.
K30 Sub-Family Reference Manual, Rev. 6, Nov 2011
Description
Freescale Semiconductor, Inc.

Related parts for MK30DN512ZVLK10