HD6417615 Hitachi Semiconductor, HD6417615 Datasheet - Page 748

no-image

HD6417615

Manufacturer Part Number
HD6417615
Description
Hardware Manual
Manufacturer
Hitachi Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417615ARBPV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417615ARF
Quantity:
8
Part Number:
HD6417615ARF
Manufacturer:
HIT
Quantity:
5 510
Part Number:
HD6417615ARF
Manufacturer:
ABB
Quantity:
5 510
Part Number:
HD6417615ARF
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417615ARFV
Manufacturer:
HITACHI
Quantity:
239
Part Number:
HD6417615ARFV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417615ARFV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
17.4.3
The H-UDI can be reset in two ways.
17.5
The H-UDI pins can be placed in the boundary scan mode stipulated by IEEE1149.1 by setting a
command in SDIR.
17.5.1
The SH7615 supports the three essential instructions defined in IEEE1149.1 (BYPASS,
SAMPLE/PRELOAD, and EXTEST) and optional instructions (CLAMP, HIGHZ, and IDCODE).
BYPASS: The BYPASS instruction is an essential standard instruction that operates the bypass
register. This instruction shortens the shift path to speed up serial data transfer involving other
chips on the printed circuit board. While this instruction is executing, the test circuit has no effect
on the system circuits. The instruction code is 1111.
SAMPLE/PRELOAD: The SAMPLE/PRELOAD instruction inputs values from the SH7615’s
internal circuitry to the boundary scan register, outputs values from the scan path, and loads data
onto the scan path. When this instruction is executing, the SH7615’s input pin signals are
transmitted directly to the internal circuitry, and internal circuit values are directly output
externally from the output pins. The SH7615’s system circuits are not affected by execution of
this instruction. The instruction code is 0100.
In a SAMPLE operation, a snapshot of a value to be transferred from an input pin to the internal
circuitry, or a value to be transferred from the internal circuitry to an output pin, is latched into the
boundary scan register and read from the scan path. Snapshot latching is performed in
synchronization with the rise of TCK in the Capture-DR state. Snapshot latching does not affect
normal operation of the SH7615.
In a PRELOAD operation, an initial value is set in the parallel output latch of the boundary scan
register from the scan path prior to the EXTEST instruction. Without a PRELOAD operation,
when the EXTEST instruction was executed an undefined value would be output from the output
pin until completion of the initial scan sequence (transfer to the output latch) (with the EXTEST
instruction, the parallel output latch value is constantly output to the output pin).
The H-UDI is reset when the TRST signal is held at 0.
When TRST = 1, the H-UDI can be reset by inputting at least five TCK clock cycles while
TMS = 1.
H-UDI Reset
Boundary Scan
Supported Instructions