MCU 5V 512K 100-TQFP

DF3052BX25V

Manufacturer Part Number
DF3052BX25V
Description
MCU 5V 512K 100-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300Hr
Datasheets

Specifications of DF3052BX25V

Core Processor
H8/300H
Core Size
16-Bit
Speed
25MHz
Connectivity
SCI, SmartCard
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
70
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF3052BX25V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 13 Serial Communication Interface
Rev. 3.00 Mar 21, 2006 page 484 of 814
REJ09B0302-0300
Receiving Serial Data
follow. When switching from asynchronous mode to synchronous mode, make sure that the
ORER, PER, and FER flags are cleared to 0. If the FER or PER flag is set to 1 the RDRF flag
will not be set and both transmitting and receiving will be disabled.
Figure 13.18 shows a sample flowchart for receiving serial data and indicates the procedure to
No
No
Read ORER flag in SSR
Clear RE bit to 0 in SCR
Read RDRF flag in SSR
RDRF flag to 0 in SSR
from RDR, and clear
Read receive data
Start receiving
ORER = 1?
RDRF = 1?
receiving?
Finished
Initialize
Figure 13.18 Sample Flowchart for Serial Receiving (1)
End
Yes
Yes
No
continued on next page
Yes
Error handling
1
2
4
5
3
1. SCI initialization: the receive data function
2, 3. Receive error handling: if a receive error
4. SCI status check and receive data read:
5. To continue receiving serial data: check the
of the RxD pin is selected automatically.
occurs, read the ORER flag in SSR, then
after executing the necessary error
handling, clear the ORER flag to 0. Neither
transmitting nor receiving can resume
while the ORER flag remains set to 1.
read SSR, check that the RDRF flag is set
to 1, then read receive data from RDR and
clear the RDRF flag to 0. Notification that
the RDRF flag has changed from 0 to 1 can
also be given by the RXI interrupt.
RDRF flag, read RDR, and clear the RDRF
flag to 0 before the MSB (bit 7) of the
current frame is received. If the DMAC is
activated by a receive-data-full interrupt
request (RXI) to read RDR, the RDRF flag
is cleared automatically.

Related parts for DF3052BX25V