Specifications of DS72030W200FPV

Core Size
32bit
Program Memory Size
32KB
Cpu Speed
200MHz
Digital Ic Case Style
QFP
No. Of Pins
240
Supply Voltage Range
1.1V To 1.3V
Operating Temperature Range
-20°C To +85°C
Svhc
No SVHC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
21.5
21.5.1
Operation of the D/A converter can be disabled or enabled using the standby control register. The
initial setting is for operation of the D/A converter to be halted. Register access is enabled by
canceling module standby mode. For details, see section 28, Power-Down Modes.
21.5.2
When this LSI enters software standby mode with D/A conversion enabled, the D/A outputs are
retained, and the analog power supply current is equal to as during D/A conversion. If the analog
power supply current needs to be reduced in software standby mode, clear the DAOE0, DAOE1,
and DAE bits to 0 to disable the D/A outputs.
21.5.3
The reliability of this LSI may be adversely affected if the following voltage ranges are exceeded.
1. AVcc and AVss input voltages
2. Setting range of AVref input voltage
21.5.4
Before entering deep standby mode, disable D/A conversion by clearing all of the DAOE0,
DAOE1, and DAE bits to 0. If the LSI enters deep standby mode with D/A conversion enabled,
the states on the D/A converter pins are not guaranteed.
Input voltages AVcc and AVss should be PVcc − 0.3 V ≤ AVcc ≤ PVcc and AVss = PVss. Do
not leave the AVcc and AVss pins open when the A/D converter or D/A converter is not in use
and in software standby mode. When not in use, connect AVcc to the power supply (PVcc) and
AVss to the ground (PVss).
Set the reference voltage range of the AVref pin as 3.0 V ≤ AVref ≤ AVcc.
Usage Notes
Module Standby Mode Setting
D/A Output Hold Function in Software Standby Mode
Setting Analog Input Voltage
D/A Conversion in Deep Standby Mode
Rev. 3.00 Sep. 28, 2009 Page 1051 of 1650