Specifications of DS72030W200FPV

Core Size
32bit
Program Memory Size
32KB
Cpu Speed
200MHz
Digital Ic Case Style
QFP
No. Of Pins
240
Supply Voltage Range
1.1V To 1.3V
Operating Temperature Range
-20°C To +85°C
Svhc
No SVHC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Section 5 Exception Handling
5.2.4
(1)
When the MRES pin is driven low, this LSI enters the manual reset state. To reset this LSI without
fail, the MRES pin should be kept at the low level for at least 20-tcyc. In the manual reset state,
the CPU’s internal state is initialized, but all the on-chip peripheral module registers are not
initialized. In the manual reset state, manual reset exception handling starts when the MRES pin is
first driven low for a fixed period and then returned to high. The CPU operates as follows:
1. The initial value (execution start address) of the program counter (PC) is fetched from the
2. The initial value of the stack pointer (SP) is fetched from the exception handling vector table.
3. The vector base register (VBR) is cleared to H'00000000, the interrupt mask level bits (I3 to
4. The values fetched from the exception handling vector table are set in the PC and SP, and the
(2)
When a setting is made for a manual reset to be generated in the WDT’s watchdog timer mode,
and WTCNT of the WDT overflows, this LSI enters the manual reset state.
When manual reset exception processing is started by the WDT, the CPU operates in the same
way as when a manual reset was caused by the MRES pin.
(3)
When a manual reset is generated, the bus cycle is retained, but if a manual reset occurs while the
bus is released or during DMAC burst transfer, manual reset exception handling will be deferred
until the CPU acquires the bus. The CPU and the BN bit in IBNR of the INTC are initialized by a
manual reset. The FPU and other modules are not initialized.
Rev. 3.00 Sep. 28, 2009 Page 132 of 1650
REJ09B0313-0300
exception handling vector table.
I0) of the status register (SR) are initialized to H'F (B'1111), and the BO and CS bits are
initialized. The BN bit in IBNR of the INTC is also initialized to 0.
program begins executing.
Manual Reset by Means of MRES Pin
Manual Reset Initiated by WDT
Note in Manual Reset
Manual Reset