DS72030W200FPV Renesas Electronics America, DS72030W200FPV Datasheet - Page 994

no-image

DS72030W200FPV

Manufacturer Part Number
DS72030W200FPV
Description
MPU, 32BIT, SH7203, ROMLESS, 240QFP
Manufacturer
Renesas Electronics America
Series
SH7200r
Datasheet

Specifications of DS72030W200FPV

Core Size
32bit
Program Memory Size
32KB
Cpu Speed
200MHz
Digital Ic Case Style
QFP
No. Of Pins
240
Supply Voltage Range
1.1V To 1.3V
Operating Temperature Range
-20°C To +85°C
Svhc
No SVHC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Section 19 Controller Area Network (RCAN-TL1)
In Event Triggered Mode RCAN-TL1 will clear a transmit pending flag after successful
transmission of its corresponding message or when a transmission abort is requested successfully
from the TXCR. In Time Trigger Mode, TXPR for the Mailboxes from 30 to 24 is NOT cleared
after a successful transmission, in order to keep transmitting at each programmed basic cycle. The
TXPR flag is not cleared if the message is not transmitted due to the CAN node losing the
arbitration process or due to errors on the CAN bus, and RCAN-TL1 automatically tries to
transmit it again unless its DART bit (Disable Automatic Re-Transmission) is set in the Message-
Control of the corresponding Mailbox. In such case (DART set), the transmission is cleared and
notified through Mailbox Empty Interrupt Flag (IRR8) and the correspondent bit within the Abort
Acknowledgement Register (ABACK).
If the status of the TXPR changes, the RCAN-TL1 shall ensure that in the identifier priority
scheme (MCR2 = 0), the highest priority message is always presented for transmission in an
intelligent way even under circumstances such as bus arbitration losses or errors on the CAN bus.
Please refer to the Application Note for details.
When the RCAN-TL1 changes the state of any TXPR bit position to a '0', an empty slot interrupt
(IRR8) may be generated. This indicates that either a successful or an aborted mailbox
transmission has just been made. If a message transmission is successful it is signalled in the
TXACK register, and if a message transmission abortion is successful it is signalled in the
ABACK register. By checking these registers, the contents of the Message of the corresponding
Mailbox may be modified to prepare for the next transmission.
• TXPR1
Note: * It is possible only to write a ‘1’ for a Mailbox configured as transmitter.
Bits 15 to 0 — Requests the corresponding Mailbox to transmit a CAN Frame. The bit 15 to 0
corresponds to Mailbox-31 to 16 respectively. When multiple bits are set, the order of the
transmissions is governed by the MCR2 – CAN-ID or Mailbox number.
Rev. 3.00 Sep. 28, 2009 Page 962 of 1650
REJ09B0313-0300
Initial value:
R/W:
Bit:
R/W* R/W* R/W* R/W* R/W* R/W* R/W* R/W* R/W* R/W* R/W* R/W* R/W* R/W* R/W* R/W*
15
0
14
0
13
0
12
0
11
0
10
0
9
0
TXPR1[15:0]
8
0
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
0

Related parts for DS72030W200FPV