Specifications of DS72030W200FPV

Core Size
32bit
Program Memory Size
32KB
Cpu Speed
200MHz
Digital Ic Case Style
QFP
No. Of Pins
240
Supply Voltage Range
1.1V To 1.3V
Operating Temperature Range
-20°C To +85°C
Svhc
No SVHC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Section 7 User Break Controller (UBC)
Rev. 3.00 Sep. 28, 2009 Page 206 of 1650
REJ09B0313-0300
Bit
9, 8
7, 6
5, 4
3, 2
Bit Name
CP[1:0]
CD[1:0]
ID[1:0]
RW[1:0]
Initial
Value
00
00
00
00
R/W
R/W
R/W
R/W
R/W
Description
I-Bus Bus Select
Select the bus when the bus cycle of the break
condition is the I bus cycle. However, when the C bus
cycle is selected, this bit is invalidated (only the CPU
cycle).
00: Condition comparison is not performed
01: Break condition is the internal CPU bus
10: Break condition is the internal DMA bus
11: Break condition is the internal CPU bus
C Bus Cycle/I Bus Cycle Select
Select the C bus cycle or I bus cycle as the bus cycle
of the break condition.
00: Condition comparison is not performed
01: Break condition is the C bus (F bus or M bus) cycle
10: Break condition is the I bus cycle
11: Break condition is the C bus (F bus or M bus) cycle
Instruction Fetch/Data Access Select
Select the instruction fetch cycle or data access cycle
as the bus cycle of the break condition. If the
instruction fetch cycle is selected, select the C bus
cycle.
00: Condition comparison is not performed
01: Break condition is the instruction fetch cycle
10: Break condition is the data access cycle
11: Break condition is the instruction fetch cycle or
Read/Write Select
Select the read cycle or write cycle as the bus cycle of
the break condition.
00: Condition comparison is not performed
01: Break condition is the read cycle
10: Break condition is the write cycle
11: Break condition is the read cycle or write cycle
data access cycle