DS72030W200FPV Renesas Electronics America, DS72030W200FPV Datasheet - Page 1224

no-image

DS72030W200FPV

Manufacturer Part Number
DS72030W200FPV
Description
MPU, 32BIT, SH7203, ROMLESS, 240QFP
Manufacturer
Renesas Electronics America
Series
SH7200r
Datasheet

Specifications of DS72030W200FPV

Core Size
32bit
Program Memory Size
32KB
Cpu Speed
200MHz
Digital Ic Case Style
QFP
No. Of Pins
240
Supply Voltage Range
1.1V To 1.3V
Operating Temperature Range
-20°C To +85°C
Svhc
No SVHC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Section 23 USB 2.0 Host/Function Module (USB)
(1)
The TYPE bit in PIPEPCFG is used to specify the transfer type for each pipe. The transfer types
that can be set for the pipes are as follows.
1. DCP: No setting is necessary (fixed at control transfer).
2. PIPE1 and PIPE2: These should be set to bulk transfer or isochronous transfer.
3. PIPE3 to PIPE5: These should be set to bulk transfer.
4. PIPE6 and PIPE7: These should be set to interrupt transfer.
(2)
The EPNUM bit in PIPECFG is used to set the endpoint number for each pipe. The DCP is fixed
at endpoint 0. The other pipes can be set from endpoint 1 to endpoint 15.
1. DCP: No setting is necessary (fixed at end point 0).
2. PIPE1 to PIPE7: The endpoint numbers from 1 to 15 should be selected and set.
(3)
The MXPS bit in DCPMAXP and PIPEMAXP is used to specify the maximum packet size for
each pipe. DCP and PIPE1 to PIPE5 can be set to any of the maximum pipe sizes defined by the
USB specification. For PIPE6 and PIPE7, 64 bytes are the upper limit of the maximum packet
size. The maximum packet size should be set before beginning the transfer (PID = BUF).
1. DCP: 64 should be set when using high-speed operation.
2. DCP: Select and set 8, 16, 32, or 64 when using full-speed operation.
3. PIPE1 to PIPE5: 512 should be set when using high-speed bulk transfer.
4. PIPE1 to PIPE5: Select and set 8, 16, 32, or 64 when using full-speed bulk transfer.
5. PIPE1 and PIPE2: Set a value between 1 and 1024 when using high-speed isochronous
6. PIPE1 and PIPE2: Set a value between 1 and 1023 when using full-speed isochronous transfer.
7. PIPE6 and PIPE7: Set a value between 1 and 64.
The high bandwidth transfers used with interrupt transfers and isochronous transfers are not
supported.
Rev. 3.00 Sep. 28, 2009 Page 1192 of 1650
REJ09B0313-0300
These should be set so that the combination of the DIR bit and EPNUM bit is unique.
transfer.
Transfer Types
Endpoint Number
Maximum Packet Size Setting