DS72030W200FPV Renesas Electronics America, DS72030W200FPV Datasheet - Page 588

no-image

DS72030W200FPV

Manufacturer Part Number
DS72030W200FPV
Description
MPU, 32BIT, SH7203, ROMLESS, 240QFP
Manufacturer
Renesas Electronics America
Series
SH7200r
Datasheet

Specifications of DS72030W200FPV

Core Size
32bit
Program Memory Size
32KB
Cpu Speed
200MHz
Digital Ic Case Style
QFP
No. Of Pins
240
Supply Voltage Range
1.1V To 1.3V
Operating Temperature Range
-20°C To +85°C
Svhc
No SVHC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Section 11 Multi-Function Timer Pulse Unit 2 (MTU2)
Table 11.53 Register Settings for Complementary PWM Mode
Note:
Rev. 3.00 Sep. 28, 2009 Page 556 of 1650
REJ09B0313-0300
Channel
3
4
Timer dead time data register
(TDDR)
Timer cycle data register
(TCDR)
Timer cycle buffer register
(TCBR)
Subcounter (TCNTS)
Temporary register 1 (TEMP1)
Temporary register 2 (TEMP2)
Temporary register 3 (TEMP3)
* Access can be enabled or disabled according to the setting of bit 0 (RWE) in TRWER
(timer read/write enable register).
Counter/Register
TCNT_3
TGRA_3
TGRB_3
TGRC_3
TGRD_3
TCNT_4
TGRA_4
TGRB_4
TGRC_4
TGRD_4
Description
Start of up-count from value set
in dead time register
Set TCNT_3 upper limit value
(1/2 carrier cycle + dead time)
PWM output 1 compare register
TGRA_3 buffer register
PWM output 1/TGRB_3 buffer
register
Up-count start, initialized to
H'0000
PWM output 2 compare register
PWM output 3 compare register
PWM output 2/TGRA_4 buffer
register
PWM output 3/TGRB_4 buffer
register
Set TCNT_4 and TCNT_3 offset
value (dead time value)
Set TCNT_4 upper limit value
(1/2 carrier cycle)
TCDR buffer register
Subcounter for dead time
generation
PWM output 1/TGRB_3
temporary register
PWM output 2/TGRA_4
temporary register
PWM output 3/TGRB_4
temporary register
Read/Write from CPU
Maskable by TRWER
setting*
Maskable by TRWER
setting*
Maskable by TRWER
setting*
Always readable/writable
Always readable/writable
Maskable by TRWER
setting*
Maskable by TRWER
setting*
Maskable by TRWER
setting*
Always readable/writable
Always readable/writable
Maskable by TRWER
setting*
Maskable by TRWER
setting*
Always readable/writable
Read-only
Not readable/writable
Not readable/writable
Not readable/writable

Related parts for DS72030W200FPV