DS72030W200FPV Renesas Electronics America, DS72030W200FPV Datasheet - Page 1086

no-image

DS72030W200FPV

Manufacturer Part Number
DS72030W200FPV
Description
MPU, 32BIT, SH7203, ROMLESS, 240QFP
Manufacturer
Renesas Electronics America
Series
SH7200r
Datasheet

Specifications of DS72030W200FPV

Core Size
32bit
Program Memory Size
32KB
Cpu Speed
200MHz
Digital Ic Case Style
QFP
No. Of Pins
240
Supply Voltage Range
1.1V To 1.3V
Operating Temperature Range
-20°C To +85°C
Svhc
No SVHC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Section 22 AND/NAND Flash Memory Controller (FLCTL)
(3)
• Command access mode: Performs an access by specifying a command to be issued from the
• Sector access mode: Performs a read or write in sector units by specifying a sector and controls
(4)
• A sector is the basic unit of access and comprised of 512-byte data and 16-byte control code.
• The position of the ECC in the control code can be specified in 4-byte units.
• User information can be written to the control code other than the ECC.
(5)
• 8-byte ECC code is generated and error check is performed for a sector (512-byte data + 16-
• Error correction capability is up to three errors.
• In a write operation, an ECC code is generated for data and control code prior to the ECC. The
• In a read operation, an ECC error is checked for data and control code prior to the ECC. An
• An error correction is not performed even when an ECC error occurs. Error corrections must
(6)
• When a program error or erase error occurs, the error is reflected on the error source flags.
• When a read error occurs, an ECC in the control code is other than 0. This read error is
• When an ECC error occurs, perform an error correction, specify another sector to be replaced,
Rev. 3.00 Sep. 28, 2009 Page 1054 of 1650
REJ09B0313-0300
FLCTL to flash memory, address, and data size to be input or output. Read, write, or erasure of
data without ECC processing can be achieved.
ECC-code generation and check. By specifying the number of sectors, the continuous sectors
can be read or written.
The 16-byte control code includes 8-byte ECC.
byte control code). (Note that the ECC code generation in the 16-byte control code and the
number of bytes to be checked differ depending on the specifications.)
control code following the ECC is not considered.
ECC on the control code in the FIFO is replaced with the check result by the ECC circuit, not
an ECC code read from flash memory.
be performed by software.
Interrupts for each source can be specified.
reflected on the ECC error source flag.
and copy the contents of the block to another sector as required.
Access Modes: The FLCTL can select one of the following two access modes.
Sectors and Control Codes
ECC
Data Error

Related parts for DS72030W200FPV