R5S77631Y266BGV Renesas Electronics America, R5S77631Y266BGV Datasheet - Page 1179

IC SUPERH MPU ROMLESS 499BGA

R5S77631Y266BGV

Manufacturer Part Number
R5S77631Y266BGV
Description
IC SUPERH MPU ROMLESS 499BGA
Manufacturer
Renesas Electronics America
Series
SuperH® SH7780r
Datasheet

Specifications of R5S77631Y266BGV

Core Processor
SH-4A
Core Size
32-Bit
Speed
266MHz
Connectivity
Audio Codec, I²C, MMC, SCI, SIM, SIO, SSI, USB
Peripherals
DMA, LCD, POR, WDT
Number Of I /o
107
Program Memory Type
ROMless
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
1.15 V ~ 1.35 V
Data Converters
A/D 4x10b; D/A 2x8b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
499-BGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
R5S77631Y266BGV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
(4)
Figure 27.17 shows a sample flowchart for serial transmission.
Use the following procedure for serial data transmission after enabling the SCIF for transmission.
In serial transmission, the SCIF operates as described below.
1. When data is written into SCFTDR, the SCIF transfers the data from SCFTDR to SCTSR and
2. When data is transferred from SCFTDR to SCTSR and transmission is started, consecutive
starts transmitting. Confirm that the TDFE flag in SCFSR is set to 1 before writing transmit
data to SCFTDR. The number of data bytes that can be written is at least 64 (transmit trigger
setting).
transmit operations are performed until there is no transmit data left in SCFTDR. When the
number of transmit data bytes in SCFTDR falls to or below the transmit trigger number set in
Serial Data Transmission (Clocked Synchronous Mode)
Write transmit data to SCFTDR
Clear TE bit in SCSCR to 0
Read TEND flag in SCFSR
Read TDFE flag in SCFSR
TEND flag in SCFSR to 0
and clear TDFE flag and
Start of transmission
All data transmitted?
End of transmission
Figure 27.17 Sample Serial Transmission Flowchart
Initialization
TEND = 1?
TDFE = 1?
Yes
Yes
Yes
No
No
No
[1]
Section 27 Serial Communication Interface with FIFO (SCIF)
[2]
[3]
[1] SCIF initialization:
[2] SCIF status check and transmit data
[3] Serial transmission continuation
See sample SCIF initialization
flowchart in figure 27.16.
write:
Read SCFSR and check that the
TDFE flag is set to 1, then write
transmit data to SCFTDR, and clear
the TDFE flag to 0. The transition of
the TDFE flag from 0 to 1 can also be
identified by a TXI interrupt.
procedeure:
To continue serial transmission, read
1 from the TDFE flag to confirm that
writing is possible, them write data to
SCFTDR, and then clear the TDFE
flag to 0.
Rev. 2.00 May 22, 2009 Page 1109 of 1982
REJ09B0256-0200