MPC8536DS Freescale Semiconductor, MPC8536DS Datasheet - Page 1330

BOARD DEV SYSTEM MPC8536E

MPC8536DS

Manufacturer Part Number
MPC8536DS
Description
BOARD DEV SYSTEM MPC8536E
Manufacturer
Freescale Semiconductor
Series
PowerQUICC III™r
Type
MPUr
Datasheets

Specifications of MPC8536DS

Contents
Board, Software and Documentation
Processor Series
MPC85xx
Core
e500
Data Bus Width
32 bit
Maximum Clock Frequency
667 MHz
Operating Supply Voltage
- 0.3 V to + 1.21 V
Maximum Operating Temperature
+ 105 C
Data Ram Size
32 KB
Interface Type
SPI, USB
Program Memory Type
DDR2, DDR3, SDRAM
Core Size
32 Bit
Program Memory Size
544KB
Cpu Speed
1.5GHz
Digital Ic Case Style
BGA
No. Of Pins
783
Supply Voltage Range
0.95V To 1.05V
Rohs Compliant
Yes
For Use With/related Products
MPC8536
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Enhanced Secure Digital Host Controller
20-56
CMD6
CMD7
CMD8
CMD9
CMD10
CMD11
CMD12
CMD13
CMD14
CMD15
CMD16
CMD17
CMD18
CMD19
INDEX
CMD
(3)
Type
adtc
adtc
adtc
adtc
ac
ac
ac
ac
ac
ac
ac
ac
[31:26] Set to 0
[25:24] Access
[23:16] Index
[15:8] Value
[7:3] Set to 0
[2:0] Cmd Set
[31:6] RCA
[15:0] stuff bits
[31:0] stuff bits
[31:6] RCA
[15:0] stuff bits
[31:6] RCA
[15:0] stuff bits
[31:0] stuff bits
[31:6] RCA
[15:0] stuff bits
[31:6] RCA
[15:0] stuff bits
[31:0] block length
[31:0] data address
[31:0] data address
[31:0] data address
MPC8536E PowerQUICC III Integrated Processor Reference Manual, Rev. 1
Argument
Table 20-27. Commands for MMC/SD (continued)
Resp
R1b
R1b
R1b
R1
R2
R2
R1
R1
R1
R1
R1
SELECT/DESELECT_CARD Command toggles a card between the
SEND_EXT_CSD
SEND_CSD
SEND_CID
STOP_TRANSMISSION
SEND_STATUS
GO_INACTIVE_STATE
SET_BLOCKLEN
READ_SINGLE_BLOCK
READ_MULTIPLE_BLOCK
SWITCH
READ_DAT_UNTIL_STOP
Abbreviation
Reserved
Reserved
Switches the mode of operation of the
selected card or modifies the
EXT_CSD registers. Refer to the
MultiMediaCard System Specification
version 4.0 final draft 2 for details.
stand-by and transfer states or
between the programming and
disconnect states. In both cases, the
card is selected by its own relative
address and gets deselected by any
other address; address 0 deselects all.
The card sends its EXT_CSD register
as a block of data, with block size of
512 bytes.
Addressed card sends its card-specific
data (CSD) on the SDHC_CMD line.
Addressed card sends its
card-identification (CID) on the
SDHC_CMD line.
Reads data stream from the card
starting at the given address until
STOP_TRANSMISSION is received.
Forces the card to stop transmission.
Addressed card sends its status
register.
Sets the card to inactive state in order
to protect the card stack against
communication breakdowns.
Sets the block length (in bytes) for all
following block commands (read and
write). Default block length is specified
in the CSD.
Reads a block of the size selected by
the SET_BLOCKLEN command.
Continuously transfers data blocks
from card to host until interrupted by a
stop command.
Description
Freescale Semiconductor
1

Related parts for MPC8536DS